Exhaled breath condensate: a comprehensive update

  • Hasib Ahmadzai

    Hasib Ahmadzai is a medical researcher from the Prince of Wales Hospital Respiratory Department and the University of New South Wales (UNSW) Inflammation and Infection Research Centre (IIRC). His research has primarily focused on the immunological aspects of sarcoidosis as well as the role of exhaled breath condensate in monitoring pulmonary sarcoidosis. He has also recently completed his MBBS BSc (Med) Hons degree at UNSW in 2012 and is working as a medical officer at The Canberra Hospital.

    , Shuying Huang

    Shuying Huang is a medical researcher at the University of New South Wales and a member of the Inflammation and Infection Research Centre, Sydney, Australia. She undertook the Bachelor of Science (Medicine) Honours program in 2012, with a research focus on the granulomatous inflammation and peripheral anergy of sarcoidosis and the use of exhaled breath condensate in the investigation of inflammatory biomarkers.

    , Ravin Hettiarachchi

    Ravin M. Hettiarachchi is currently a final year medical student studying at the University of New South Wales, Sydney, Australia. He completed his thesis in exhaled breath analysis in lung transplant recipients in 2011 with First Class Honours working with the Inflammation and Infection Research Centre, University of New South Wales, Sydney, Australia.

    , Jiun-Lih Lin

    Jiun-Lih (Jerry) Lin is a Resident Medical Officer at the Royal North Shore Hospital in Sydney Australia. He received his medical degree from the University of New South Wales, with relevant research experience in the field of chronic obstructive pulmonary disease, exhaled breath condensate as well as studies into the role of oxidative stress/anti-oxidant balance in the development of pulmonary diseases.

    , Paul S. Thomas

    Professor Paul S. Thomas is a clinician and researcher at UNSW, Sydney, Australia. He has an active research group with which he has published over 140 original peer-reviewed journal articles on respiratory medicine, plus books, book chapters and over 250 peer-reviewed abstracts. His research interests are in the fields of breath analysis and translational research focussing on asthma, sarcoidosis, occupational lung diseases, together with screening for lung cancer, mesothelioma and other lung diseases.

    EMAIL logo
    and Qi Zhang

    Qi Zhang is a medical researcher working in the Prince of Wales Hospital Respiratory Department and the University of New South Wales (UNSW) Inflammation and Infection Research Centre (IIRC). His primary research is in exhaled breath condensate. Qi has published journal articles and presented various papers at international conferences on this topic. He is also the leading author of a book chapter on respiratory diseases and oxidative stress.

Abstract

Since the late 1990s, a surge in interest in the analysis of exhaled breath condensate (EBC) resulted in the American Thoracic Society and European Respiratory Society (ATS/ERS) organising a Task Force in 2001 to develop guidelines on EBC collection and measurement of biomarkers. This Task Force published their guidelines in 2005 based on literature and expert opinions at that time, and multiple shortcomings and knowledge deficits were also identified. The clinical application of EBC collection and its biomarkers are currently still limited by several of these knowledge gaps, hence further guidelines for standardisation are required to ensure external validity. Using related articles produced since the publication of the ATS/ERS Task Force report, this paper attempts to provide a comprehensive update to the original guideline and review the methodological shortcomings identified. This review can hopefully serve as a yardstick for future studies involving this emerging clinical tool.

Introduction

Exhaled breath condensate (EBC) is a non-invasive method of sampling airway lining fluid (ALF). It contains a number of molecules which may act as biomarkers that indicate disease processes occurring in the lungs or systemically.

Since the late 1990s, a surge in interest in the analysis of EBC resulted in the American Thoracic Society (ATS) and European Respiratory Society (ERS) organising a Task Force in 2001 to develop guidelines on EBC collection, measuring biomarkers and reviewing the current literature on EBC. This Task Force published their guidelines in 2005 based on the current literature and expert opinions at that time [1]. In 2012, despite the growing number of EBC-related publications, there have been no further updates in the literature comprehensively reviewing the methodological shortcomings identified by the ATS/ERS Task Force.

It is recognised that EBC collection and analysis is limited to translational research and is currently not used in clinical practice. This review aims to expand on the ATS/ERS Task Force and summarise the current literature in regards to EBC. As the technique is being utilised more frequently throughout the world, standardisation of techniques and devices is required so as to ensure that progress continues to be made and that the research is comparable between studies.

This review will outline the issues that lead to variability when examining EBC. When possible, it will aim to make recommendations based on the current peer reviewed literature to ensure that these limitations are minimised. It will also outline the biomarkers that have been studied to date in EBC, their role in various diseases and the methods used for their detection and measurement. An important focus will be placed on current assay techniques.

The reviewers of this article wish to echo the words of those from the ATS/ERS Task Force to ensure that standardisation of techniques should not stand in the way of innovation and the utility of EBC has a significant potential to grow with continued research.

Methodological issues of EBC

Origins of EBC

Air is warmed and humidified as it travels through the respiratory tree. As warm, fully saturated breath is exhaled from the lungs and comes into contact with the cold EBC collecting apparatus, it condenses into either liquid or ice depending on the cooling temperature. This condensate consists of mainly water (>99%) and a small amount of ALF [2]. This ALF is believed to have been derived from the respiratory surface lining fluids when energy from air turbulence vibrates the respiratory wall, and creates nebulised droplets. ALF droplets may also be released when closed airway or alveoli suddenly open during inspiration, providing energy to overcome surface tension [3]. The constituents of ALF are assumed to represent the respiratory tree lining fluids and their relative percentage is the essence of EBC studies.

Unlike bronchoalveolar lavage or induced sputum, EBC does not collect respiratory cells. It measures the concentration of biomarkers believed to be directly influenced by these cells, with an alteration in concentrations indicating a corresponding change in the cellular composition and activity [4, 5].

Collection devices

There are different types of EBC collection devices used in various studies. While all devices function by cooling exhaled breath, they employ a variety of designs, cooling methods and condensation materials. These include commercial devices, such as EcoScreen® [6] (Figure 1), EcoScreen-2 [7], EcoScreen Turbo [8], RTubeTM [9], and TURBO-DECCS [10], as well as custom-made devices [11] and devices for specific patient groups, including children [12], infants [13, 14] and mechanically ventilated patients [15, 16]. A comparison of biomarkers measured in EBC that were collected using different devices is shown in Table 1. The design and coating material used in the device is shown to influence the biomarker of interest. Due to distinct physical and chemical characteristics of each distinct biomarker, there is currently no universal device that is ideal for all biomarkers. The choice of an appropriate collecting device depends on the particular biomarker of interest [25].

Figure 1 Picture of an EcoScreen® collection device.
Figure 1

Picture of an EcoScreen® collection device.

Table 1

A comparison of EBC and EBC biomarkers collected using different devices.

EcoScreen®RTubeTMCustom-made device (material)/Other devicesSubject characteristic(s), sample size, p-value
VolumeHealthy controls, n=30, p<0.001 [9]
== (Siliconised glass)Healthy controls, n=6, p<0.05 [17]
↓ (PET)– Healthy controls, n=10 [18]
– Healthy controls, n=10, p<0.001 [19]
pH==– Healthy controls [n=10], asthmatic patients [n=10], COPD patients [n=10] and subjects with acute cold [n=10], n=40, p=0.754 [20]
– Healthy adults, n=30, p=0.419 [9]
– Healthy controls, n=10 [18]
– Healthy controls, n=9, p=0.059 [21]
===Healthy controls, n=6, p=0.34 [17]
== (PET)Healthy controls, n=10, p=0.46 [19]
aHealthy controls [n=6], asthmatic patients [n=10] and subjects with allergic rhinitis [n=7], n=23, p<0.0001b and p=0.04c [10]
a↓ (Glass)Healthy controls, n=12, p<0.05d and p<0.001e [22]
Total protein (amount)== (Silicone)Healthy controls, n=6, p=0.017 [17]
= (Glass)
== (PET)Healthy controls, n=10, p=0.18 [19]
Total protein (concentration)== (PET)Healthy controls, n=10, p=0.51 [19]
== (Glass)Healthy controls, n=12, p=0.004 [22]
Mucin=== (Siliconised glass)Healthy controls, n=6, p=0.52 [17]
Albumin==↑ (Silicone)In vitro experiment, p=0.03 [23]
↑ (Glass)
= (Aluminium)
= (Polypropylene)
= (Teflon®)
==↑ (Glass)Healthy controls, n=23, p<0.008 [23]
= (Silicone)
= (Aluminium)
= (Polypropylene)
= (Teflon®)
Cysteinyl leukotrienesHealthy controls, n=30, p<0.001 [9]
EotaxinHealthy controls, n=30, p=0.01 [9]
8-isoprostanes==↑ (Silicone)– In vitro experiment, p=0.09 [23]
↑ (Glass)

= (Aluminium)
– Healthy controls, n=23, p<0.001f, p<0.02g and p=0.763h [23]
= (Polypropylene)
= (Teflon®)
Conductivity of non-lyophilised EBC== (PET)Healthy controls, n=10, p=0.087 [19]
Oxides of nitrogen== (Siliconised glass)Healthy controls, n=6, p<0.001 [17]
Malondialdehyde== (Tygon®)COPD patients, n=10, coefficient correlation: r=0.9, p<0.01 [24]
Hexanal==COPD patients, n=10, r=0.9, p<0.01 [24]
Heptanal==COPD patients, n=10, r=0.9, p<0.01 [24]
Nonanal==COPD patients, n=10, r=0.8, p<0.05 [24]

↑, Significantly higher in value (p<0.05); ↓, significantly lower in value (p<0.05); =, no statistical significance (p>0.05); PET, portable EcoScreen turbo. amore alkaline; bwithout argon de-aeration prior to pH measurement; cwith argon de-aeration prior to pH measurement; dEcoScreen vs. RTube; eEcoScreen vs. glass device; fsilicone coating vs. glass, aluminium, polypropylene, Teflon coatings and EcoScreen; gglass coating vs. polypropylene and Teflon coatings and EcoScreen; hcomparison between aluminium, polypropylene, Teflon coatings and EcoScreen).

Condensation devices

Condensation of EBC vapour can be achieved at temperatures of 4°C or lower [26]. The cooling of the exhaled breath vapour has been achieved through various means, including wet ice, wet ice with salt, dry ice, liquid nitrogen, cooling sleeve and electrical refrigerating systems [22, 26, 27]. Depending on the temperature, condensates are collected in either a liquid, solid, or a mixture of both states [26]. The condensation temperature used can influence biomarkers differently (Table 2). Each biomarker has different characteristics, thus researchers should try to optimise the collection conditions when investigating biomarkers that are near the limits of detection. The exact basis of these differences is not well understood, but will related to water solubility, degradation, either spontaneous or by enzyme activity, or to freeze-thawing and oxidation [26]. It is thus important for condensation temperatures to be reported, to facilitate comparison of data across laboratories.

Table 2

Influence of condensation temperatures on various biomarkers.

Change in level of biomarkers as temperature decreasesCondensation temperatures compared, °CEBC deviceSubject characteristics, sample size, p-value
Volume−10 vs. −5TURBO-DECCSHealthy subjects, n=24, p<0.01 [27]
−10 vs. 0
−10 vs. 5
−5 vs. 5
0 vs. 5TURBO-DECCSHealthy subjects, n=24, p<0.05 [27]
−50 vs. −20RTubeIn vitro experiment [28]
−50 vs. 0
−20 vs. 4Glass CMDHealthy subjects, n=40, p<0.0001 [26]
pHa−70 vs. −20RTubeHealthy subjects, n=12, p<0.05 [22]
Total protein (amount)−20 vs. 4Glass CMDHealthy subjects, n=20, p<0.0014 [26]
Total protein (concentration)=−70 vs. −20RTubeHealthy subjects, n=12, p>0.05 [22]
=−20 vs. 4Glass CMDHealthy subjects, n=20, p=0.052 [26]
Hydrogen peroxide (amount)−10 vs. 5TURBO-DECCSHealthy subjects, n=24, p<0.05 [27]
Hydrogen peroxide (concentration)−10 vs. 0TURBO-DECCSHealthy subjects, n=24, p<0.01 [27]
0 vs. 5
−20 vs. 4Glass CMDHealthy subjects, n=20, p=0.009 [26]
Malondialdehyde (amount)−10 vs. 5TURBO-DECCSHealthy subjects, n=24, p<0.01 [27]
−10 vs. 0TURBO-DECCSHealthy subjects, n=24, p<0.05 [27]
−5 vs. 5
Malondialdehyde (concentration)−10 vs. 5TURBO-DECCSHealthy subjects, n=24, p<0.01 [26]
−10 vs. 0TURBO-DECCSHealthy subjects, n=24, p<0.05 [27]
Acetone−50 vs. −20RTubeIn vitro experiment [28]
−50 vs. 0
Conductivity of lyophilised EBC−10 vs. 5TURBO-DECCSHealthy subjects, n=24, p<0.01 [27]
−10 vs. 0TURBO-DECCSHealthy subjects, n=24, p<0.05 [27]
−5 vs. 5
Conductivity of vacuum-evaporated EBC−20 vs. 4Glass CMDHealthy subjects, n=20, p=0.042 [26]
Nitrate/nitrite (concentration)=−20 vs. 4Glass CMDHealthy subjects, n=20, p=0.63 [26]

TURBO-DECCS, transportable unit for research on biomarkers obtained from disposable exhaled condensate collection systems; CMD, custom-made device; amore acidic.

Effect of respiratory patterns on EBC biomarkers

The concentration of various EBC biomarkers is found to be influenced by changes in respiratory patterns. This can have significant implications in diseases such as chronic obstructive pulmonary disease (COPD) where patients’ expiratory flow rate and tidal volume are reduced.

Increased minute ventilation and tidal volume are independently associated with greater EBC volume [17, 19, 29] without a decrease in lyophilised conductivity [30], indicating that breathing pattern changes are capable of increasing EBC output without altering the dilution by water vapour. This is probably due to a combination of increased expired volume of breath, greater aerosolisation of ALF with increased turbulent airflow and increased recruitment of alveoli [29, 31].

EBC is thought to be produced mainly from the central rather than the peripheral lung regions, when studied using radioactive aerosol [32]. The large airways and alveoli are likely to release different biomarkers. Changes in respiratory pattern, including exercise [33], hyperventilation [19], changes in respiratory flow rate [29] and mechanical ventilation, are found to affect different biomarkers differently (Table 3). Biomarkers that are respiratory flow-dependent generally originate from the airways [34]. Biomarkers which are non-flow-dependent originate predominately from the alveoli, where flow rate plays a minimal role in these terminal air sacs [42]. EBC should be sampled during tidal breathing, especially when measuring respiratory pattern sensitive biomarkers [1]. Additionally, monitoring and standardising expired breath volume may be necessary in future device designs to reduce variability in ventilation and hence in EBC mediator levels.

Table 3

Summary of different respiratory manoeuvres on EBC biomarkers.

BiomarkersRespiratory manoeuvresChanges in concentrationReference
H2O2↑ Exhalation flow rate[34]
Volume↑ Tidal volume/↑ Minute ventilation[17, 19, 30, 34–37]
Resistance to outflow[17]
ProteinChanges in tidal volume/minute ventilationNIL[19, 37]
Total protein (amount)Hyperventilation[19]
CysLTsChanges in minute ventilationNIL[30]
Forceful expiration
Airway narrowing
Exercise↑ (asthmatics)[38, 39]
NIL (healthy controls)[38]
Lyophilised conductivityChanges in minute ventilationNIL[30]
Forceful expiration
Airway narrowing
pHHyperventilation/HypoventilationNIL[35]
Mechanical ventilation[40]
Exercise[33]
NitriteChanges in tidal volume/minute ventilationNIL[37]
Nitrogen oxideMechanical ventilation[40]
8-IsoprostaneMechanical ventilationNIL[40]
AmmoniaExercise[33]
PropionateExercise[33]
AdenosineExercise↑ (asthmatics)[41]
NIL (healthy controls)

Standardisation of de-aeration and pH

EBC sample de-aeration or standardisation of gas in EBC is a common practice aimed at achieving stable EBC pH [20, 43]. There is currently controversy over de-aeration methods.

EBC pH is a measure of airway acidification, which is unstable in its unprocessed form [1]. The variable amount of dissolved carbon dioxide is one of the main confounding factors of EBC pH. Dissolved CO2 lowers pH and amounts are inconsistent among individuals [44, 45]. The conventional method of de-aeration is to bubble CO2-free gas, usually with argon, in order to displace CO2. Despite several laboratories attempting to standardise the argon de-aeration method, there is still no accepted protocol due to multiple variables involved [11, 46]. The lack of a defined argon de-aeration protocol leads to a range of de-gassing duration and flow rates among various laboratories, which may have led to the variable results obtained [20, 43, 47]. Since EBC pH of different patient groups changes differently during de-aeration [46], there is a need to standardise the argon de-aeration protocol per unit volume of EBC.

A novel approach of de-aeration is to bubble a known quantity of CO2 into EBC samples to standardise the pCO2 to 40mm Hg [48]. This method has been shown to achieve more consistent EBC pH compared with non-degassed samples and samples degassed by argon at a flow-rate of 300 mL/min for 2.5–10min [49]. More studies are needed to verify this new method of gas standardisation.

Due to the inefficiency of argon and CO2 in removing other volatile ions and oral contaminants, including NH4+/NH3, some have suggested lyophilisation as the method of choice for removing volatile ions [50, 51]. EBC pH of lyophilised samples will be a direct measurement of non-volatile acids, such as lactic acid, that originate from epithelial fluid [50]. However, this is not widely practiced as lyophilisation is time-consuming, requires special equipment and introduces processing errors.

Duration and efficiency of EBC collection devices

Duration of EBC collection also affects EBC volumes, however, it does not affect pH [35] or concentrations of H2O2, nitrate/nitrite, 8-isoprostane, adenosine and malondialdehyde (MDA) [1]. Despite so, findings in animal models have identified that pCO2 in EBC is negatively dependent on duration of collection [44]. A standardised collection time is therefore necessary in future EBC studies. A collection time of 10min is generally sufficient to collect condensate at ~100 μL/min (range 40–300 μL/min), producing 1–2mL of EBC per subject [52].

Reproducibility

EBC volume is arguably the only reproducible EBC parameter, provided that tidal breathing is performed during collection [1]. In general, the lack of standardisation of EBC collection methods and validation of biomarker measurement across different laboratories decrease the comparability of EBC analysis [42] despite facilitating discovery of novel biomarkers [53]. This is further complicated by the levels of many EBC biomarkers being near the lower limits of assay detection, contributing to problems of variability and validity of results [54]. Therefore, it is important to test reproducibility of each biomarker collected via various devices and to be analysed with different assays in order to find the most ideal combination for best results.

Dilution reference indicators

EBC comprises mostly condensed water vapour, and the variable dilution of the constituents has hindered its application as a representation of ALF. Without reliable measure of dilution, baseline EBC biomarker concentrations and changes in these concentrations cannot be accurately determined [55]. It is also unknown whether differences in EBC biomarker levels are due to corresponding differences in ALF or varying sizes of breath droplets arising from an identical source [3, 54, 56]. Therefore, dilution reference indicators are required to serve as comparison for calculation of true airway biomarker levels and to correct for inter-subject variability in droplet formation [42]. It must be noted that dilution is only relevant for non-volatile EBC biomarkers, and not the volatile components which are affected by different factors [57].

Over the years, three dilution reference indicators (urea, total cation concentrations, and conductivity following lyophilisation) have been proposed for use in EBC. It is essential that each of these has similar plasma and ALF concentrations [58] and that they are neither synthesised nor destroyed in the lungs [55]. Urea is a near ideal indicator because besides meeting these criteria, it also diffuses passively between ALF and plasma [54, 55]. However, plasma urea concentration can be quite variable, requiring plasma measurement during each EBC analysis, and also local urea concentration may be reduced by urease-producing bacteria during infections [54]. Conductivity is the simplest method as it is sensitive, easy and quick to perform while not requiring large volumes of EBC samples [59].

There have been conflicting views on the use of dilution reference indicators. It is thought that these indicators are redundant when multiple biomarkers are measured concurrently, as their ratios may serve as a reference or when a highly sensitive and specific assay is used [3]. Currently, many laboratories have yet to incorporate this complicated calculation method in their studies [21]. This method will perhaps only receive greater acceptance when a gold standard indicator is finally defined.

Concentration of samples

As EBC is such a diluted matrix that most biomarkers are detected near the lower limits of assay sensitivity, concentration of samples is essential for successful and reliable measurement of various biomarkers. The most promising method is lyophilisation, which is the freeze-drying process that sublimes water directly from solid to gas phase, bypassing the liquid-gas transition phase, which would require heat and degradation of samples. The resultant solute can then be reconstituted [53]. This method is effective for measuring oxidative stress biomarkers (8-iso-prostaglandin F, o-tyrosine, 8-hydroxy-2’-deoxy-guanosine), cytokines, and proteins [60–62]. However, the lack of studies investigating its reproducibility and reliability, with estimates of sample recovery limits its utility in EBC analysis to date. Another concentration method via solid phase extraction provides better recovery for cysteinyl leukotrienes [63]. To date, methods including ultra-filtration, freeze-drying, vacuum concentration, and concentration with pyrogallol red were found to be unsuitable, but may vary for each mediator [57].

Ambient air

Ambient room air contains molecules, which can interact with EBC biomarkers through several mechanisms such as directly contributing to EBC, reacting with compounds present in EBC (thus altering or consuming biomarkers) or causing biochemical or inflammatory changes in the airways [1]. Atmospheric nitric oxide (NO) has been shown to reduce exhaled H2O2 concentrations [64]. Ambient H2O2 concentrations have also been found to correspond to approximately 30% of the H2O2 concentration in the EBC of healthy calves [65]. The inspired concentration of a substance may hence affect the corresponding EBC measurement.

Temperature and humidity of inhaled air [66], as well as condensation temperatures [1, 65, 67], may influence EBC constituents (due to variable heats of vaporisation and specific heat capacities compared to pure water) such as volume [26] and pH [68] but not total protein [22]. EBC samples should not be left out at room temperature after collection, due to interactions with ambient air with potential formation and degradation of unstable or volatile biomarkers such as leukotrienes, purines, H2O2 and volatile organic compounds (VOC) [1, 52].

Ideally, environmental humidity and temperature must be recorded along with respiratory rate, minute ventilation, total exhaled volume, exhaled breath temperature and expiratory flow rates during collection in order to assess effects on EBC volumes and/or biomarker concentrations.

Age and gender

There are conflicting data on effects of gender on EBC volume [69] and H2O2 levels [70]. EBC H2O2[70] and exhaled NO levels [71] appear to correlate positively with age. Polar VOCs, including aldehydes, appear to be affected by gender, with increased levels in males suggesting metabolic gender differences [72]. In contrast, EBC pH does not appear to be affected by age [73] or gender [74]. EBC total protein appears to increase with age but is not affected by gender [69]. Additionally, body weight and height do not affect EBC volume and H2O2 concentration in adults [1].

Food and drink

Food intake and physical activity levels during the day may be responsible for changes in EBC biomarkers and may partially explain the circadian rhythm observed in biomarker concentrations [75]. Food intake prior to EBC collection has not been observed to have an effect on non-volatile mediators or pH [76]. In contrast, EBC collection 15min after drinking 1 L of either an acidic beverage (cola) or a pH neutral beverage (water) both significantly decreased EBC pH levels [77]. Several foods and beverages contain H2O2 or elevate levels of oxidants in bodily fluids, thus influencing EBC oxidant concentrations [75]. In animal studies, food intake was found to double EBC H2O2 levels 1h after morning feeding [65]. High dietary nitrite/nitrate concentrations can affect NO-related markers in EBC in non-inflamed airways [78]. When measuring mediators known to be affected by certain drinks or foods, it is advisable that subjects avoid these a few hours prior to measurement (e.g., caffeinated drinks prior to measuring adenosine) [1] and should avoid drinking large volumes prior to EBC collection.

Circadian rhythm

A recent investigation indicated a circadian change in EBC H2O2 concentrations in healthy volunteers, with highest values in the afternoon and a nadir in the morning [70, 75]. This is also the case in calves, with significantly greater EBC H2O2 and pH found in the evening compared to the morning [65]. Observations of daytime variability in biomarker concentrations indicate that consistent conditions and time of day may need to be applied to the time of collection to improve reliability [75].

Smoking

Smoking affects concentrations of 8-isoprostane, H2O2, S-nitrosothiols and nitrate in EBC [79]. In general, EBC concentrations of NO-related compounds [80], aldehydes [81, 82] and total protein may be elevated or remain unchanged with smoking [83]. Levels of 8-isoprostane, prostaglandin E2, leukotriene B4[84, 85], H2O2[70] and TNF-α [80] increased, whilst levels of IL-1β [80], glutathione (an important antioxidant) [83] and pH [76] decreased minutes after cigarette smoking. Similarly, increased levels of oxidative markers, including MDA, 8-hydroxydeoxyguanosine, superoxide dismutase and glutathione peroxidise, were identified in the EBC of smokers compared with non-smokers [86]. Smokers should thus refrain from smoking at least 3h and preferably overnight before EBC collection to minimise effects on mediator levels.

Systemic diseases

The potential effect of systemic diseases, including pulmonary [87, 88] and extrapulmonary systemic diseases [1, 89], needs to be considered in EBC studies. An approximately 20-fold greater H2O2 level has been described in the EBC of uraemic patients compared to healthy controls [90]. In one study, peritoneal dialysis and haemodialysis significantly decreased exhaled H2O2[91].

Medication

One inhalation of salbutamol or ipratropium had no effect on EBC H2O2 and thiobarbituric acid reactive substances (TBARs) concentrations in healthy subjects [70]. EBC H2O2 and FeNO are decreased in asthmatics following inhaled corticosteroid treatment [92, 93], although budesonide administration did not affect EBC nitrite levels in healthy subjects even after inducing an inflammatory response with ozone exposure [94]. Inhaled deionised water or 0.9% NaCl does not affect EBC H2O2 concentrations. However, nebulised N-acetylcysteine almost completely abolishes EBC H2O2 levels 30min after administration, although this rises almost two-fold above baseline 2.5h later [95]. A transient increase in EBC H2O2 following nebulised N-acetylcysteine has been demonstrated in patients with stable COPD [96], despite a decrease with long-term treatment [97].

Sample contamination

Gross salivary contamination can occur in EBC collection. There is an increased likelihood of oropharyngeal contamination with volatile biomarkers; e.g., most EBC ammonia arises from bacterial degradation of urea in the oropharynx [98]. Additionally, oropharyngeal bacterial flora may significantly contribute to EBC nitrite levels, since levels decrease following a chlorhexidine mouthwash [99]. High concentrations of eicosanoids have been detected in saliva [79], with prostaglandins and leukotrienes formed in the nose and mixing with oral expiratory air via the nasopharynx [79]. However, this can be controlled with mouth rinsing before collection, periodically swallowing saliva and using a nose clip. EBC must be checked with α-amylase assays to assess amylase concentrations which indicate salivary contamination [5], although significant salivary contamination has been ruled out by NMR spectroscopy studies of EBC [100, 101]. One investigation identified different cytokine profiles in EBC and saliva using a cytokine protein array to compare concentrations of 40 cytokines. This indicated that salivary contamination is negligible if validated collection methods are used [102]. There are also concerns with upper airway and nasal contamination. There are similar oral and nasal EBC protein patterns, which differ from those of saliva and demonstrate a lack of salivary phosphorous contamination and low EBC amylase activity [103].

Suggestions to further reduce contamination include use of VOC filters at the inhalation port to reduce ambient VOC contamination, tidal breathing to sample alveolar air, use of a nose clip, salivary trap and Swan-neck tubing (placing condenser inlet at a higher level than the subject’s mouth) [1, 52]. A nose clip prevents nasal inhalation of air and exhalation through the nose.

Disinfection of non-disposable apparatus components

Disinfection of non-disposable components of EBC apparatus is very important for sanitary purposes and accuracy of assays. While there have been no cases of infection being transmitted between subjects, it is a risk that has to be minimised particularly when using these devices in patient groups who may be immunocompromised.

Current disinfection practice described in the literature for reusable apparatus components has been inconsistent. These have ranged from simply rinsing with distilled water and air-drying to soaking to multiple disinfection steps involving enzymatic detergents and ethanol before rinsing and drying [104, 105]. It is important to ensure that detergents used are pH-neutral and non-reactive so as to limit any confounding of assays. Recent studies examining the influence of external contaminants on EBC, including disinfectants, found that standard disinfection protocols had measurable disinfectant contaminant signal when analysed by nuclear magnetic resonance spectroscopy. However, one study showed that the disinfectant Milton showed no signals [100]. Although water soaking alone was able to effectively remove most toxic components of disinfectant, ethanol washing was required for removal of unknown contaminants which may interfere with assays [104].

NMR spectroscopy-based metabolomics

Nuclear magnetic resonance (NMR) spectroscopy can be utilised to identify the biochemical profiles of metabolites in EBC samples. This is a reproducible technique and its methodology has been validated [100]. Although NMR has a lower sensitivity compared to enzyme-linked immunosorbent assay (ELISA) and mass spectrometry, it is a non-destructive analytical method that requires minimal sample preparation and has rapid acquisition time of about 10–15min [104]. NMR-based metabolomics of EBC may have a potential use in characterising respiratory diseases as it was able to discriminate patients with COPD [104], asthma [106], stable and unstable cystic fibrosis [107] from healthy subjects. In addition, a recent NMR spectroscopic study has also shown that the repeated use of the EcoScreen® condenser does not cause any carry-over effect and the disinfectant Milton does not alter EBC metabolomics [100], as opposed to another study that reported artificial signals when the Anacon condenser was used and disinfected with Descogen [108]. Different analytical techniques, including NMR and mass spectrometry, may be combined to improve sensitivity and further consolidate ‘breathomics’ [100].

Biomarkers in EBC

Hydrogen peroxide

Hydrogen peroxide is normally present in exhaled breath, probably from the pulmonary circulation [109]. Additionally, activation of airway epithelial and endothelial cells, neutrophils, alveolar macrophages and eosinophils leads to production of superoxide radicals and hence H2O2 production in airway inflammation. H2O2 is less reactive and soluble than other reactive oxygen species, with its neutral charge and low molecular weight allowing it to cross membranes to exit into the extracellular spaces. However, it is less stable than other oxidative stress markers such as the isoprostanes. H2O2 is volatile and readily equilibrates with air, thus its presence can be easily detected in EBC as a marker of pulmonary inflammation and oxidative stress. Compared to healthy subjects, EBC H2O2has been shown to be significantly increased in patients with asthma [92], COPD [110], bronchiectasis [111], acute respiratory distress syndrome [112], interstitial lung disease [113] and cardiothoracic surgery [114], but not cystic fibrosis [115].

Breathing patterns must be taken into consideration with all EBC H2O2 measurements [67]. EBC H2O2concentration varies with breathing patterns, decreasing after increased tidal volumes compared to normal breathing [75]. Other recent findings indicate that exhaled H2O2 concentrations can be standardised if expressed in moles per 100 L of expired air and if inhaled H2O2 levels are subtracted from exhaled H2O2[65].

EBC de-aeration is another critical factor influencing H2O2 concentrations. Although it is important to remove reactive gases to stabilise EBC biomarkers and pH, research in our laboratory indicates that argon de-gassing lowers H2O2concentrations [11]. Sample pH affects H2O2 quantitation, thus careful assay optimisation should be considered prior to H2O2 measurements [116]. EBC samples should also be rapidly stored at −80°C following collection so that H2O2 is not rapidly lost or oxidised [83]. Frozen samples may remain stable varying from 2–3 days to 2months [117]. Many studies analysing EBC H2O2 have used spectrophotometric colorimetric assays, with detection limits >0.1 μmol/L [67] and differing reaction substrates, including tetramethylbenzidine, 4-hydroxyphenylacetic acid or homovanillic acid, and using either fresh or thawed EBC samples, which explain variations in H2O2 concentrations [118]. Other methods of EBC H2O2analysis include measurement with various spectrofluorimetric techniques (fluorimetric assay) [70], as well as flow injection analysis with fluorescence detection [119] by chemiluminescent methods [120] and by immediate on-line analysis with a commercially available amperometric biosensor (Ecocheck, Jaeger, Germany) [121]. Although chemiluminescent methods have high sensitivity, detecting H2O2 in the nanomolar range, they are limited by poor day-to-day precision and typically require expensive equipment, which may not be suitable for routine clinical studies [67].

Arachidonic acid derivatives: eicosanoids

Eicosanoids represent a heterogeneous family of unsaturated fatty acid derivatives, arising from arachidonic acid, which is released from the cell wall by phospholipase A2. Cyclooxygenase or lipoxygenase enzymatic action leads to formation of prostanoids and leukotrienes, respectively, whilst actions of free-radicals lead to formation of isoprostanes [1, 83].

Prostanoids: prostaglandins, prostacyclin and thromboxanes

Prostanoids are synthesised via the cyclooxygenase pathway and include prostaglandins and thromboxanes. Prostaglandin E2(PGE2) has pro-inflammatory actions and a role in inhibiting bronchoconstriction, and has been measured in EBC samples using enzyme immunoassays (EIA) and radioimmunoassay [1, 83]. Thromboxane A2 (TxA2) is readily converted to a chemically stable form, TxB2, a potent bronchoconstrictor [79]. Hence, thromboxane synthesis is usually assessed by measuring TxB2 and EBC TxB2has been measured using EIA [83]. PGE2 is present in the EBC of healthy subjects, with upper normal limits not exceeding 75pg/mL [36], although there is variability regarding normal values [83].

Leukotrienes

Leukotrienes consist of a family of lipid mediators synthesised by leukocytes from arachidonic acid through enzymatic catalysis of 5-lipoxygenase. They are categorised into cysteinyl leukotrienes (i.e., LTC4, LTD4 and LTE4) and LTB4. Cysteinyl leukotrienes contract airway smooth muscle, increase vascular permeability, stimulate mucus secretion and decrease mucociliary clearance [79]. LTB4 is a potent neutrophil and eosinophil chemoattractant, contributing to oedema and local airway narrowing, and also increased mucus secretion [79, 122]. Leukotrienes have been measured in EBC using EIA, gas chromatography/mass spectroscopy (GC/MS) and liquid chromatography/mass spectroscopy (LC/MS) [83, 123, 124]. EBC LTB4is increased in patients with asthma [36, 125, 126], COPD [84, 127], cystic fibrosis [128] and patients undergoing cardiothoracic surgery [114]. LTB4concentrations in EBC are also elevated after sputum induction, indicating a pro-inflammatory effect of this procedure [129]. Cysteinyl leukotrienes have been widely assessed and are elevated in patients with asthma [36, 125, 126], including children [130–133]. This is consistent with the central role of leukotrienes in the pathophysiology of these respiratory conditions.

Isoprostanes

Isoprostanes are produced by free-radical lipid peroxidation of arachidonic acid, representing an in vivo marker of oxidative stress [83]. Isoprostanes have several advantages over other oxidative stress markers as they are chemically stable and are specific for lipid peroxidation. They are also useful for assessing lung oxidative stress in animal experimental models of asthma [134]. They have potent effects including smooth muscle contraction which have been implicated in the pathophysiology of various respiratory conditions [79]. 8-Isoprostane is most widely studied in EBC, usually measured using EIA although GC/MS has also been used [114]. The highest values of 8-isoprostane detected in EBC of healthy subjects were up to 50pg/mL [83]. EBC concentrations of 8-isoprostane in the μg/mL range have also been reported and that EBC concentrations were higher than BAL concentrations [5]. One study identified the importance of the inner coating of condensing devices, with highest 8-isoprostane levels detected with glass and silicon coatings compared to the Ecoscreen® [23], which may account for variability in different studies. Levels of EBC 8-isoprostane have been shown to be increased in patients with asthma – correlating with disease severity and degree of inflammation [117, 135], COPD [83, 136], ARDS [137], cystic fibrosis [138, 139], exercise-induced asthma [140], and patients undergoing cardiothoracic surgery [114].

Nitric-oxide (NO)-related products

NO has been one of the most extensively studied exhaled biomarkers of inflammation, especially in asthma and COPD [141]. NO plays an important role in inflammation, regulation of smooth muscle tone, and levels increase in response to pro-inflammatory cytokines and oxidants [53]. NO is a free radical which readily reacts with oxygen to form nitrogen oxides (NOx) or reacts with superoxide anion to form peroxynitrate – a reactive substance that may lead to production of NO-derived products. Nitrite (NO2-) and nitrate (NO3-) are readily found in ALF and are produced by the reaction of NO with oxygen and the decomposition of peroxynitrate. S-Nitrosothiols are produced by interaction of peroxynitrate with thiol- containing substances, including cysteine and glutathiones, which act as antioxidants limiting the nitrosative stress of NO-related products [83]. Nitrotyrosine is produced by the reaction of peroxynitrate with protein tyrosine residues. Nitrotyrosine can alternatively be formed by nitration of proteins using myeloperoxidase, a heme enzyme in neutrophils [142]. NO synthesis and release in the respiratory system have been indirectly assessed in EBC by quantifying levels of nitrate/nitrite, nitrotyrosine and S-nitrosothiols [83, 143]. Nitrate and nitrite have been measured in EBC of patients with asthma [53, 93], COPD [53, 144], pulmonary fibrosis [145], bronchiectasis, cystic fibrosis [146], acute lung injury [147], primary ciliary dyskinesia [148] and community acquired pneumonia [149]. However, conflicting results exist between increased or unchanged nitrate/nitrite levels in some respiratory conditions [149]. Nitrotyrosine has been found to be elevated in patients with asthma [125], COPD [53] and cystic fibrosis [150] although one study did not find it a useful marker of nitrosative stress when comparing stable patients with healthy subjects [151].

EBC nitrite and nitrate are measured by colorimetric (Griess reaction), fluorimetric [using the 2,3-diaminonapthalene (DAN) reaction] and chemiluminescence assays as well as liquid, gas and ion chromatography [152]. The reported detection limit of the DAN assay is 0.1 μm whilst the Griess reaction is higher. EBC nitrite is often detected in the 0.1 μm range, which is close to the detection limits of the former assays [1]. Nitrate is often measured indirectly following incubation with nitrate reductase [117, 152] and tends to be 5–10-folds higher than nitrite levels although this may reflect changes in inflammatory airway conditions [1]. Nitrotyrosine is best measured with mass spectrometry with the greatest sensitivity (measured in the picomolar range) [125], but can also be measured using enzyme immunoassays or high performance liquid chromatography (HPLC) [1, 83]. S-nitrosothiols are usually measured using colorimetric assays [83, 152], but can be sensitively measured using chemiluminescence analysis after reduction to NO in copper-cysteine or using ultraviolet light [153].

There is considerable variability in the normal ranges for nitrite/nitrate [83], with high day-to-day variability of EBC NOx measurements [105]. This may relate to different assays used for measurement and sample contamination. Laboratory contamination is a major problem as nitrogen oxides are present on laboratory surfaces, glassware and pipette tips [154]. Ambient nitric oxide is readily diffusible and can become oxidised, thus rapidly contaminating surfaces. Hence, precautions should be taken by rinsing collecting equipment and glassware with purified (distilled/de-ionised) water and appropriate control samples without EBC [1].

Cytokines, chemokines and growth factors

Most proteins, including cytokines, are difficult to measure reliably in EBC. Cytokines mediate inflammatory processes and have been measured in EBC by enzyme and radioimmunoassay, either individually or on multiplex platforms. Limiting factors in measurement have included low limits of detection, matrix effects and intra- and inter-assay variability [117, 155]. Recent studies have measured many different EBC cytokines, chemokines and growth factors in various pulmonary diseases using multiplex analysis and protein arrays, allowing sensitive detection of multiple factors using small volumes of EBC [61, 87, 102, 156]. The major limitation that remains is that EBC cytokine levels are usually close to assay detection limits. This may be overcome by lyophilisation, which enables removal water and other volatile substances, but may degrade biomarkers [53]. EBC lyophilisation can concentrate samples up to a factor of 30 times, thus improving sensitivity [61]. There was no relationship between EBC cytokine concentrations and storage times up to 1 year in samples stored at −80°C [157]. With newer technologies, EBC cytokine measurement may become useful in assessing airway inflammatory status for treatment monitoring and investigating disease pathophysiology [156].

Aldehydes and thiobarbituric acid-reactive substances (TBARs)

Aldehydes (MDA, hexanals, heptanals and nonenals) are lipid peroxides, measured in EBC as markers of oxidant-induced damage [81]. MDA is generated by arachidonic acid and docosahexanoic acid, and is regarded as a TBAR. EBC MDA levels are usually increased during asthma exacerbations and in COPD patients [158] compared with healthy smokers [81], and higher in smokers than non-smokers [82]. Conversely, reduced EBC glutathione indicates reduced antioxidant capacity [1, 159]. Increased MDA and decreased glutathione have been demonstrated in asthmatic children and patients with allergic rhinitis compared with healthy controls [24, 160]. These substances may be formed during sample preparation. Although the measurement is simple, current colorimetric assays and LC/MS lack specificity, with day-to-day intra-subject coefficient of variations for different aldehydes being 12%–20% [24]. Hence, these substances are not frequently used as markers of lipid peroxidation [1]. Novel measurement techniques utilise an alternate isotope-coded derivatisation assay (AIDA) in the LC/MS measurement of aldehydes, with results in good agreement with external calibration methods [161].

Adenosine

Adenosine triphosphate and its metabolites, including adenosine – a purine nucleoside, have been detected in EBC [117]. EBC adenosine has been shown to be significantly greater in patients with asthma, cystic fibrosis [162], allergic rhinitis during exercise [41] and in allergic rhinitis [163]. EBC is a useful method of measuring purinergic molecules compared with other sampling techniques, due to absence of confounding factors such as low EBC cellular and protein content [164]. EBC adenosine has been measured using LC/MS and recently using HPLC [165]. Luciferin-luciferase assays have been used for measurement of ATP as luciferin is a substrate oxidised by ATP [164]. In order to overcome varying dilution of airway droplets, the simultaneous measurement of purines and a dilution marker have been recently validated [162, 164].

Transitional metals

Transitional metals are d-block metals that form ions with two of more oxidative states. Iron (10–30 μm), copper (13–22 μm) and zinc (12–20 μm) are the most abundant redox-active transitional metals in the human body. Pivotal transitional metal-catalysed oxidative stress pathways include the production of superoxides from NADPH-dependent oxidase with subsequent production of hydroxyl radicals through the Fenton and Haber-Weiss reaction. Furthermore, iron and copper play key a role in the catalysis of many other endogenous reactions, generating reactive intermediates (Table 4).

Table 4

Redox-active metal-catalysed formation of reactive oxygen intermediates.

⋅O2- + H2O2 → OH⋅ (metal-catalysed Haber-Weiss reaction)
LOOH (lipid peroxide) → LO⋅, LO2· (alkoxyl and peroxyl radical)
Ascorbic acid + O2→ascorbyl radical, ·OH, H2O2
NAD(P)H + O2→ NAD(P)·, ·O2-, ·OH, H2O2
Catecholamines + O2→ ·O2-, ·OH, H2O2
RSH(thiols) + O2→O2-, ·OH·H2O2, RS· (thiyl radical)

Metal-catalysed reaction oxygen species can initiate destructive processes including lipid peroxidation and enzyme inactivation. Metal-catalysed formation of ·OH can result in removal of a hydrogen atom from unsaturated fatty acid, leading to lipid radical formation, destruction of cell membrane integrity and cell death. Binding of endogenous enzymes to redox-active transition metals can initiate protein oxidation and inactivation.

Many studies have examined the correlation between oxidative stress and the presence of COPD, with several oxidant biomarkers identified to be elevated in this chronic disease [166, 167]. Hydrogen peroxide (H2O2), a by-product of many transition metal catalysed reactions, is an example of a strong oxidant elevated in EBC of COPD patients. Other oxidative stress markers including 8-isoprostane [167] and nitric oxide related products [168] have also been demonstrated to be elevated in the EBC of COPD patients. Novel biomarkers with potential utility for early diagnosis and prognosis of COPD are of significant interest.

Exhaled breath DNA

Small amounts of DNA and epithelial cells, which are believed to originate from the lower respiratory tract, are also detectable in EBC [169–171]. Oxidative stress to cells in the respiratory tract results in DNA mutations, which lead to changes in cell cycling, growth promotion, DNA repair, apoptosis, and can induce angiogenesis and cellular invasion. These mutations can potentially be detected in the EBC of patients with lung cancer using PCR technology [172].

It has been reported that a significantly greater proportion of patients with non-small cell lung cancer have 3p microsatellite alterations or loss of heterozygosity in EBC compared to controls [173], with overlapping profiles of microsatellite alterations in DNA from EBC and tumour tissues [174]. It has also been demonstrated that p53 mutations are present in EBC of patients with lung cancer, while no mutations were found in controls [175]. The oncogene KRAS has also been found in EBC of patients with lung cancer and interestingly levels were shown to decrease significantly following surgical tumour resection [176]. Detection of the epidermal growth factor receptor (EGFR) gene mutation has also been demonstrated in the EBC of a patient with squamous cell carcinoma of the lung [177]. Gene promoter methylation can also be detected in the EBC of lung cancer patients and is significantly associated with lung cancer status [178]. Genetic alterations consistent with neoplasia could be a significant marker of tumorgenesis, which may be useful for early lung cancer diagnosis.

Human papilloma virus (HPV) DNA has also been identified at significantly greater frequencies in the EBC of patients with lung cancer compared to controls [179]. In addition, EBC has been used for rapid detection of microbial DNA and RNA to demonstrate bacterial and viral lung infections [180] and in infective exacerbations of COPD [181]. However, results have been disappointing for detection of Mycobacterium tuberculosis DNA in patients with tuberculosis [182, 183] as well as Pseudomonas aeruginosa and Burkholderia cepacia from patients with cystic fibrosis [184]. This may relate to the dilute nature of EBC and small quantities of DNA present in these infections.

Conclusions

The clinical application of EBC collection and its biomarkers are limited by several factors and standardisation is required to ensure external validity. This review has outlined the limitations in EBC collection techniques which may contribute to the variability in the results. Issues relating to many of the factors affecting the reliability of EBC analysis, such as gas-standardisation when examining pH and sample contamination are yet to be resolved to date. Therefore, further research is still required.

The recent use of metabolomics, which is able to detect several metabolites simultaneously, has important utility and is opening up several new opportunities to develop breath patterns that may be able to characterise disease states. Despite this, the major limitation to the clinical use of EBC is still the inadequate sensitivity of assays even with recent developments in lyophilisation and assay techniques.

Overall, the technique of EBC has been developing since the ATS/ERS Task Force publication and will continue to grow over the coming years. With continued research, EBC analysis may one day be used in clinical practice in the near future.


Corresponding author: Paul S. Thomas, Department of Respiratory Medicine, Prince of Wales Hospital, Randwick, NSW 2031, Australia Phone: +61 2 93824620, Fax: +61 2 93824627

About the authors

Hasib Ahmadzai

Hasib Ahmadzai is a medical researcher from the Prince of Wales Hospital Respiratory Department and the University of New South Wales (UNSW) Inflammation and Infection Research Centre (IIRC). His research has primarily focused on the immunological aspects of sarcoidosis as well as the role of exhaled breath condensate in monitoring pulmonary sarcoidosis. He has also recently completed his MBBS BSc (Med) Hons degree at UNSW in 2012 and is working as a medical officer at The Canberra Hospital.

Shuying Huang

Shuying Huang is a medical researcher at the University of New South Wales and a member of the Inflammation and Infection Research Centre, Sydney, Australia. She undertook the Bachelor of Science (Medicine) Honours program in 2012, with a research focus on the granulomatous inflammation and peripheral anergy of sarcoidosis and the use of exhaled breath condensate in the investigation of inflammatory biomarkers.

Ravin Hettiarachchi

Ravin M. Hettiarachchi is currently a final year medical student studying at the University of New South Wales, Sydney, Australia. He completed his thesis in exhaled breath analysis in lung transplant recipients in 2011 with First Class Honours working with the Inflammation and Infection Research Centre, University of New South Wales, Sydney, Australia.

Jiun-Lih Lin

Jiun-Lih (Jerry) Lin is a Resident Medical Officer at the Royal North Shore Hospital in Sydney Australia. He received his medical degree from the University of New South Wales, with relevant research experience in the field of chronic obstructive pulmonary disease, exhaled breath condensate as well as studies into the role of oxidative stress/anti-oxidant balance in the development of pulmonary diseases.

Paul S. Thomas

Professor Paul S. Thomas is a clinician and researcher at UNSW, Sydney, Australia. He has an active research group with which he has published over 140 original peer-reviewed journal articles on respiratory medicine, plus books, book chapters and over 250 peer-reviewed abstracts. His research interests are in the fields of breath analysis and translational research focussing on asthma, sarcoidosis, occupational lung diseases, together with screening for lung cancer, mesothelioma and other lung diseases.

Qi Zhang

Qi Zhang is a medical researcher working in the Prince of Wales Hospital Respiratory Department and the University of New South Wales (UNSW) Inflammation and Infection Research Centre (IIRC). His primary research is in exhaled breath condensate. Qi has published journal articles and presented various papers at international conferences on this topic. He is also the leading author of a book chapter on respiratory diseases and oxidative stress.

Conflict of interest statement

Authors’ conflict of interest disclosure: The authors stated that there are no conflicts of interest regarding the publication of this article.

Research funding: None declared.

Employment or leadership: None declared.

Honorarium: None declared.

References

1. Horváth I, Hunt J, Barnes PJ. Exhaled breath condensate: methodological recommendations and unresolved questions. Eur Respir J 2005;26:523–48.10.1183/09031936.05.00029705Search in Google Scholar PubMed

2. Effros RM, Hoagland KW, Bosbous M, Castillo D, Foss B, Dunning M, et al. Dilution of respiratory solutes in exhaled condensates. Am J Respir Crit Care Med 2002;165:663–9.10.1164/ajrccm.165.5.2101018Search in Google Scholar PubMed

3. Hunt J. Exhaled breath condensate: an overview. Immunol Allergy Clin North Am 2007;27:587–96.10.1016/j.iac.2007.09.001Search in Google Scholar PubMed PubMed Central

4. Balbi B, Pignatti P, Corradi M, Baiardi P, Bianchi L, Brunetti G, et al. Bronchoalveolar lavage, sputum and exhaled clinically relevant inflammatory markers: values in healthy adults. Eur Respir J 2007;30:769–81.10.1183/09031936.00112306Search in Google Scholar PubMed

5. Jackson AS, Sandrini A, Campbell C, Chow S, Thomas PS, Yates DH. Comparison of biomarkers in exhaled breath condensate and bronchoalveolar lavage. Am J Respir Crit Care Med 2007;175:222–7.10.1164/rccm.200601-107OCSearch in Google Scholar PubMed

6. Rosias PP, Robroeks CM, Kester A, den Hartog GJ, Wodzig WK, Rijkers GT, et al. Biomarker reproducibility in exhaled breath condensate collected with different condensers. Eur Respir J 2008;31:934–42.10.1183/09031936.00073207Search in Google Scholar PubMed

7. Hoffmeyer F, Weiß T, Lehnert M, Pesch B, Berresheim H, Henry J, et al. Increased metal concentrations in exhaled breath condensate of industrial welders. J Environ Monit 2011;13:212–8.10.1039/C0EM00225ASearch in Google Scholar PubMed

8. Koskela HO, Purokivi MK, Nieminen RM, Moilanen E. Asthmatic cough and airway oxidative stress. Respir Physiol Neurobiol 2012;181:346–50.10.1016/j.resp.2012.04.006Search in Google Scholar PubMed

9. Soyer OU, Dizdar EA, Keskin O, Lilly C, Kalayci O. Comparison of two methods for exhaled breath condensate collection. Allergy 2006;61:1016–8.10.1111/j.1398-9995.2006.01064.xSearch in Google Scholar PubMed

10. Mutti A, Corradi M, Goldoni M, Vettori MV, Bernard A, Apostoli P. Exhaled metallic elements and serum pneumoproteins in asymptomatic smokers and patients with COPD or asthma. Chest 2006;129:1288–97.10.1378/chest.129.5.1288Search in Google Scholar PubMed PubMed Central

11. Lin J-L, Bonnichsen MH, Thomas PS. Standardization of exhaled breath condensate: effects of different de-aeration protocols on pH and H2O2 concentrations. J Breath Res 2011;5:011001.10.1088/1752-7155/5/1/011001Search in Google Scholar PubMed

12. Rosias PP, Robroeks CM, Van De Kant KD, Rijkers GT, Zimmermann LJ, Van Schayck CP, et al. Feasibility of a new method to collect exhaled breath condensate in pre-school children. Pediatr Allergy Immunol 2010;21:e235–44.10.1111/j.1399-3038.2009.00909.xSearch in Google Scholar PubMed

13. Vogelberg C, Würfel C, Knoetzsch A, Kahlert A, Range U, Leupold W. Exhaled breath condensate pH in infants and children with acute and recurrent wheezy bronchitis. Pediatr Pulmonol 2007;42:1166–72.10.1002/ppul.20712Search in Google Scholar PubMed

14. Moeller A, Franklin P, Hall GL, Horak F, Wildhaber JH, Stick SM. Measuring exhaled breath condensates in infants. Pediatr Pulmonol 2006;41:184–7.10.1002/ppul.20362Search in Google Scholar PubMed

15. Korovesi I, Papadomichelakis E, Orfanos SE, Giamarellos-Bourboulis EJ, Livaditi O, Pelekanou A, et al. Exhaled breath condensate in mechanically ventilated brain-injured patients with no lung injury or sepsis. Anesthesiology 2011;114: 1118–29.10.1097/ALN.0b013e31820d84dbSearch in Google Scholar PubMed

16. Carter SR, Davis CS, Kovacs EJ. Exhaled breath condensate collection in the mechanically ventilated patient. Respir Med 2012;106:601–13.10.1016/j.rmed.2012.02.003Search in Google Scholar PubMed PubMed Central

17. Liu J, Conrad DH, Chow S, Tran VH, Yates DH, Thomas PS. Collection devices influence the constituents of exhaled breath condensate. Eur Respir J 2007;30:807–8.10.1183/09031936.00080207Search in Google Scholar PubMed

18. Koczulla AR, Huttmann EM, Greulich T, Jorres R, Schmid S, Noeske S, et al. Comparison of two devices and two breathing patterns for exhaled breath condensate sampling. Am J Respir Crit Care Med 2011;183:A4470.10.1164/ajrccm-conference.2011.183.1_MeetingAbstracts.A4470Search in Google Scholar

19. Hüttmann E-M, Greulich T, Hattesohl A, Schmid S, Noeske S, Herr C, et al. Comparison of two devices and two breathing patterns for exhaled breath condensate sampling. PLoS ONE 2011;6:e27467.10.1371/journal.pone.0027467Search in Google Scholar PubMed PubMed Central

20. Koczulla R, Dragonieri S, Schot R, Bals R, Gauw S, Vogelmeier C, et al. Comparison of exhaled breath condensate pH using two commercially available devices in healthy controls, asthma and COPD patients. Respir Res 2009;10:78–85.10.1186/1465-9921-10-78Search in Google Scholar PubMed PubMed Central

21. Leung TF, Li CY, Yung E, Liu EK, Lam CW, Wong GW. Clinical and technical factors affecting pH and other biomarkers in exhaled breath condensate. Pediatr Pulmonol 2006;41:87–94.10.1002/ppul.20296Search in Google Scholar PubMed

22. Czebe K, Barta I, Antus B, Valyon M, Horváth I, Kullmann T. Influence of condensing equipment and temperature on exhaled breath condensate pH, total protein and leukotriene concentrations. Respir Med 2008;102:720–5.10.1016/j.rmed.2007.12.013Search in Google Scholar PubMed

23. Rosias PP, Robroeks CM, Niemarkt HJ, Kester AD, Vernooy JH, Suykerbuyk J, et al. Breath condenser coatings affect measurement of biomarkers in exhaled breath condensate. Eur Respir J 2006;28:1036–41.10.1183/09031936.06.00110305Search in Google Scholar PubMed

24. Corradi M, Folesani G, Andreoli R, Manini P, Bodini A, Piacentini G, et al. Aldehydes and glutathione in exhaled breath condensate of children with asthma exacerbation. Am J Respir Crit Care Med 2003;167:395–9.10.1164/rccm.200206-507OCSearch in Google Scholar PubMed

25. Chow S, Yates DH, Thomas PS. Reproducibility of exhaled breath condensate markers. Eur Respir J 2008;32:1124–6.10.1183/09031936.00085408Search in Google Scholar PubMed

26. Vyas A, Zhang Q, Gunaratne S, Lee W, Lin J-L, Lin J-S, et al. The effect of temperature on exhaled breath condensate collection. J Breath Res 2012;6:036002.10.1088/1752-7155/6/3/036002Search in Google Scholar PubMed

27. Goldoni M, Caglieri A, Andreoli R, Poli D, Manini P, Vettori M, et al. Influence of condensation temperature on selected exhaled breath parameters. Pulm Med 2005;5:1–9.10.1186/1471-2466-5-10Search in Google Scholar PubMed PubMed Central

28. Loyola BR, Bhushan A, Schivo M, Kenyon NJ, Davis CE. Temperature changes in exhaled breath condensate collection devices affect observed acetone concentrations. J Breath Res 2008;2:037005.10.1088/1752-7155/2/3/037005Search in Google Scholar PubMed

29. Borrill ZL, Roy K, Singh D. Exhaled breath condensate biomarkers in COPD. Eur Respir J 2008;32:472–86.10.1183/09031936.00116107Search in Google Scholar PubMed

30. Debley JS, Ohanian AS, Spiekerman CF, Aitken ML, Hallstrand TS. Effects of bronchoconstriction, minute ventilation, and deep inspiration on the composition of exhaled breath condensate. Chest 2011;139:16–22.10.1378/chest.10-0101Search in Google Scholar PubMed PubMed Central

31. Davidsson A, Naidu Sjosward K, Lundman L, Schmekel B. Quantitative assessment and repeatability of chlorine in exhaled breath condensate. Respiration 2005;72:529–36.10.1159/000087679Search in Google Scholar PubMed

32. Bondesson E, Jansson LT, Bengtsson T, Wollmer P. Exhaled breath condensate — site and mechanisms of formation. J Breath Res 2009;3:016005.10.1088/1752-7155/3/1/016005Search in Google Scholar PubMed

33. Greenwald R, Ferdinands JM, Teague WG. Ionic determinants of exhaled breath condensate pH before and after exercise in adolescent athletes. Pediatr Pulmonol 2009;44:768–77.10.1002/ppul.21055Search in Google Scholar PubMed

34. Schleiss MB, Holz O, Behnke M, Richter K, Magnussen H, Jorres RA. The concentration of hydrogen peroxide in exhaled air depends on expiratory flow rate. Eur Respir J 2000;16:1115–8.10.1034/j.1399-3003.2000.16f16.xSearch in Google Scholar PubMed

35. Vaughan J, Ngamtrakulpanit L, Pajewski TN, Turner R, Nguyen TA, Smith A, et al. Exhaled breath condensate pH is a robust and reproducible assay of airway acidity. Eur Respir J 2003;22:889–94.10.1183/09031936.03.00038803Search in Google Scholar PubMed

36. Montuschi P, Barnes PJ. Exhaled leukotrienes and prostaglandins in asthma. J Allergy Clin Immunol 2002;109: 615–20.10.1067/mai.2002.122461Search in Google Scholar PubMed

37. McCafferty JB, Bradshaw TA, Tate S, Greening AP, Innes JA. Effects of breathing pattern and inspired air conditions on breath condensate volume, pH, nitrite, and protein concentrations. Thorax 2004;59:694–8.10.1136/thx.2003.016949Search in Google Scholar PubMed PubMed Central

38. Bikov A, Gajdocsi R, Huszar E, Szili B, Lazar Z, Antus B, et al. Exercise increases exhaled breath condensate cysteinyl leukotriene concentration in asthmatic patients. J Asthma 2010;47:1057–62.10.1080/02770903.2010.512690Search in Google Scholar PubMed

39. Carraro S, Corradi M, Zanconato S, Alinovi R, Pasquale MF, Zacchello F, et al. Exhaled breath condensate cysteinyl leukotrienes are increased in children with exercise-induced bronchoconstriction. J Allergy Clin Immunol 2005;115:764–70.10.1016/j.jaci.2004.10.043Search in Google Scholar PubMed

40. Roca O, Gómez-Ollés S, Cruz M-J, Muñoz X, Griffiths MJ, Masclans JR. Mechanical ventilation induces changes in exhaled breath condensate of patients without lung injury. Respir Med 2010;104:822–8.10.1016/j.rmed.2010.01.013Search in Google Scholar PubMed

41. Csoma Z, Huszár E, Vizi E, Vass G, Szabó Z, Herjavecz I, et al. Adenosine level in exhaled breath increases during exercise-induced bronchoconstriction. Eur Respir J 2005;25:873–8.10.1183/09031936.05.00110204Search in Google Scholar PubMed

42. Montuschi P. Review: analysis of exhaled breath condensate in respiratory medicine: methodological aspects and potential clinical applications. Ther Adv Respir Dis 2007;1:5–23.10.1177/1753465807082373Search in Google Scholar PubMed

43. Papaioannou A, Loukides S, Minas M, Kontogianni K, Bakakos P, Gourgoulianis K, et al. Exhaled breath condensate pH as a biomarker of COPD severity in ex-smokers. Respir Res 2011;12:67.10.1186/1465-9921-12-67Search in Google Scholar PubMed PubMed Central

44. Reinhold P, Jaeger J, Schroeder C. Evaluation of methodological and biological influences on the collection and composition of exhaled breath condensate. Biomarkers 2006;11:118–42.10.1080/13547500600572764Search in Google Scholar PubMed

45. Borrill Z, Starkey C, Vestbo J, Singh D. Reproducibility of exhaled breath condensate pH in chronic obstructive pulmonary disease. Eur Respir J 2005;25:269–74.10.1183/09031936.05.00085804Search in Google Scholar PubMed

46. Prieto L, Orosa B, Barato D, Marin J. The effect of different periods of argon deaeration on exhaled breath condensate pH. J Asthma 2011;48:319–23.10.3109/02770903.2011.560321Search in Google Scholar PubMed

47. MacNee W, Rennard SI, Hunt JF, Edwards LD, Miller BE, Locantore NW, et al. Evaluation of exhaled breath condensate pH as a biomarker for COPD. Respir Med 2011;105:1037–45.10.1016/j.rmed.2011.02.009Search in Google Scholar PubMed

48. Antus B, Barta I, Kullmann T, Lazar Z, Valyon M, Horvath I, et al. Assessment of exhaled breath condensate pH in exacerbations of asthma and chronic obstructive pulmonary disease: a longitudinal study. Am J Respir Crit Care Med 2010;182:1492–7.10.1164/rccm.201003-0451OCSearch in Google Scholar PubMed

49. Kullmann T, Barta I, Lázár Z, Szili B, Barát E, Valyon M, et al. Exhaled breath condensate pH standardised for CO2 partial pressure. Eur Respir J 2007;29:496–501.10.1183/09031936.00084006Search in Google Scholar PubMed

50. Effros RM, Casaburi R, Porszasz J. Assessment of exhaled breath condensate pH. Am J Respir Crit Care Med 2011;183:952–3.10.1164/ajrccm.183.7.952Search in Google Scholar PubMed

51. Effros RM, Casaburi R, Su J, Dunning M, Torday J, Biller J, et al. The effects of volatile salivary acids and bases on exhaled breath condensate pH. Am J Respir Crit Care Med 2006;173:386–92.10.1164/rccm.200507-1059OCSearch in Google Scholar PubMed PubMed Central

52. Chapman EA, Thomas PS, Yates DH. Breath analysis in asbestos-related disorders: a review of the literature and potential future applications. J Breath Res 2010;4:034001.10.1088/1752-7155/4/3/034001Search in Google Scholar PubMed

53. Grob NM, Aytekin M, Dweik RA. Biomarkers in exhaled breath condensate: a review of collection, processing and analysis. J Breath Res 2008;2:037004.10.1088/1752-7155/2/3/037004Search in Google Scholar PubMed PubMed Central

54. Montuschi P. New perspectives in monitoring lung inflammation: analysis of exhaled breath condensate. Boca Raton, FL: CRC Press, 2005.Search in Google Scholar

55. Effros RM. Exhaled breath condensates and COPD. Eur Respir J 2009;33:1238.10.1183/09031936.00191608Search in Google Scholar PubMed

56. Effros RM. Exhaled breath condensate: delusion or dilution? Chest 2010;138:471–2.10.1378/chest.10-0821Search in Google Scholar PubMed

57. Rosias P. Methodological aspects of exhaled breath condensate collection and analysis. J Breath Res 2012;6:027102.10.1088/1752-7155/6/2/027102Search in Google Scholar PubMed

58. Effros RM, Casaburi R, Porszasz J, Morales EM, Rehan V. Exhaled breath condensates: analyzing the expiratory plume. Am J Respir Crit Care Med 2012;185:803–4.10.1164/rccm.201109-1702EDSearch in Google Scholar PubMed PubMed Central

59. Dressel H, Müller F, Fischer R, Römmelt H, Hohlfeld JM, Behr J, et al. Independent information of nonspecific biomarkers in exhaled breath condensate. Respiration 2010;80:401–9.10.1159/000319945Search in Google Scholar PubMed

60. Kurova VS, Anaev EC, Kononikhin AS, Fedorchenko KY, Popov IA, Kalupov TL, et al. Proteomics of exhaled breath: methodological nuances and pitfalls. Clin Chem Lab Med 2009;47:706–12.10.1515/CCLM.2009.166Search in Google Scholar PubMed

61. Sack U, Scheibe R, Wötzel M, Hammerschmidt S, Kuhn H, Emmrich F, et al. Multiplex analysis of cytokines in exhaled breath condensate. Cytometry A 2006;69A:169–72.10.1002/cyto.a.20231Search in Google Scholar PubMed

62. Syslová K, Kačer P, Kuzma M, Pankrácová A, Fenclová Z, Vlčková Š, et al. LC-ESI-MS/MS method for oxidative stress multimarker screening in the exhaled breath condensate of asbestosis/silicosis patients. J Breath Res 2010;4:017104.10.1088/1752-7155/4/1/017104Search in Google Scholar

63. Debley JS, Hallstrand TS, Monge T, Ohanian A, Redding GJ, Zimmerman J. Methods to improve measurement of cysteinyl leukotrienes in exhaled breath condensate from subjects with asthma and healthy controls. J Allergy Clin Immunol 2007;120:1216–7.10.1016/j.jaci.2007.06.029Search in Google Scholar

64. Latzin P, Griese M. Exhaled hydrogen peroxide, nitrite and nitric oxide in healthy children: decrease of hydrogen peroxide by atmospheric nitric oxide. Eur J Med Res 2002;7:353–8.Search in Google Scholar

65. Knobloch H, Becher G, Decker M, Reinhold P. Evaluation of H2O2 and pH in exhaled breath condensate samples: methodical and physiological aspects. Biomarkers 2008;13:319–41.10.1080/13547500701831440Search in Google Scholar

66. Kullmann T, Barta I, Antus B, Valyon M, Horváth I. Environmental temperature and relative humidity influence exhaled breath condensate pH. Eur Respir J 2008;31:474–5.10.1183/09031936.00128007Search in Google Scholar

67. Stolarek R, Bialasiewicz P, Król M, Nowak D. Breath analysis of hydrogen peroxide as a diagnostic tool. Clin Chim Acta 2010;411:1849–61.10.1016/j.cca.2010.08.031Search in Google Scholar

68. Koczulla AR, Noeske S, Herr C, Dette F, Pinkenburg O, Schmid S, et al. Ambient temperature impacts on pH of exhaled breath condensate. Respirology 2010;15:155–9.10.1111/j.1440-1843.2009.01664.xSearch in Google Scholar

69. Bloemen K, Lissens G, Desager K, Schoeters G. Determinants of variability of protein content, volume and pH of exhaled breath condensate. Respir Med 2007;101:1331–7.10.1016/j.rmed.2006.10.008Search in Google Scholar

70. Nowak D, Kalucka S, Białasiewicz P, Król M. Exhalation of H2O2 and thiobarbituric acid reactive substances (TBARs) by healthy subjects. Free Radic Biol Med 2001;30:178–86.10.1016/S0891-5849(00)00457-3Search in Google Scholar

71. Haight RR, Gordon RL, Brooks SM. The effects of age on exhaled breath nitric oxide levels. Lung 2006;184:113–9.10.1007/s00408-005-2570-3Search in Google Scholar PubMed

72. Hubbard HF, Sobus JR, Pleil JD, Madden MC, Tabucchi S. Application of novel method to measure endogenous VOCs in exhaled breath condensate before and after exposure to diesel exhaust. J Chromatogr B Analyt Technol Biomed Life Sci 2009;877:3652–8.10.1016/j.jchromb.2009.09.008Search in Google Scholar PubMed

73. Brooks SM, Haight RR, Gordon RL. Age does not affect airway pH and ammonia as determined by exhaled breath measurements. Lung 2006;184:195–200.10.1007/s00408-005-2580-1Search in Google Scholar

74. Paget-Brown AO, Ngamtrakulpanit L, Smith A, Bunyan D, Hom S, Nguyen A, et al. Normative data for pH of exhaled breath condensate. Chest 2006;129:426–30.10.1378/chest.129.2.426Search in Google Scholar

75. Gajdocsi R, Bikov A, Antus B, Horváth I, Barnes PJ, Kharitonov SA. Assessment of reproducibility of exhaled hydrogen peroxide concentration and the effect of breathing pattern in healthy subjects. J Aerosol Med Pulm Drug Deliv 2011;24:271–5.10.1089/jamp.2011.0875Search in Google Scholar

76. Calušić AL, Varnai VM, Macan J. Acute effects of smoking and food consumption on breath condensate pH in healthy adults. Exp Lung Res 2011;37:92–100.10.3109/01902148.2010.521616Search in Google Scholar

77. Kullmann T, Barta I, Antus B, Horváth I. Drinking influences exhaled breath condensate acidity. Lung 2008;186:263–8.10.1007/s00408-008-9086-6Search in Google Scholar

78. Marteus H, Törnberg DC, Weitzberg E, Schedin U, Alving K. Origin of nitrite and nitrate in nasal and exhaled breath condensate and relation to nitric oxide formation. Thorax 2005;60:219–25.10.1136/thx.2004.030635Search in Google Scholar

79. Montuschi P, Barnes PJ. Analysis of exhaled breath condensate for monitoring airway inflammation. Trends Pharmacol Sci 2002;23:232–7.10.1016/S0165-6147(02)02020-5Search in Google Scholar

80. Garey KW, Neuhauser MM, Robbins RA, Danziger LH, Rubinstein I. Markers of inflammation in exhaled breath condensate of young healthy smokers. Chest 2004;125:22–6.10.1378/chest.125.1.22Search in Google Scholar PubMed

81. Corradi M, Rubinstein I, Andreoli R, Manini P, Caglieri A, Poli D, et al. Aldehydes in exhaled breath condensate of patients with chronic obstructive pulmonary disease. Am J Respir Crit Care Med 2003;167:1380–6.10.1164/rccm.200210-1253OCSearch in Google Scholar PubMed

82. Andreoli R, Manini P, Corradi M, Mutti A, Niessen WM. Determination of patterns of biologically relevant aldehydes in exhaled breath condensate of healthy subjects by liquid chromatography/atmospheric chemical ionization tandem mass spectrometry. Rapid Commun Mass Spectrom 2003;17:637–45.10.1002/rcm.960Search in Google Scholar PubMed PubMed Central

83. Koutsokera A, Loukides S, Gourgoulianis KI, Kostikas K. Biomarkers in the exhaled breath condensate of healthy adults: mapping the path towards reference values. Curr Med Chem 2008;15:620–30.10.2174/092986708783769768Search in Google Scholar PubMed

84. Kostikas K, Gaga M, Papatheodorou G, Karamanis T, Orphanidou D, Loukides S. Leukotriene B4 in exhaled breath condensate and sputum supernatant in patients with COPD and asthma. Chest 2005;127:1553–9.10.1378/chest.127.5.1553Search in Google Scholar PubMed

85. Lin JL, Thomas PS. Current perspectives of oxidative stress and its measurement in chronic obstructive pulmonary disease. COPD 2010;7:291–306.10.3109/15412555.2010.496818Search in Google Scholar PubMed

86. Doruk S, Ozyurt H, Inonu H, Erkorkmaz U, Saylan O, Seyfikli Z. Oxidative status in the lungs associated with tobacco smoke exposure. Clin Chem Lab Med 2011;49:2007–12.10.1515/CCLM.2011.698Search in Google Scholar PubMed

87. Edmé JL, Tellart AS, Launay D, Neviere R, Grutzmacher C, Boulenguez C, et al. Cytokine concentrations in exhaled breath condensates in systemic sclerosis. Inflamm Res 2008;57:151–6.10.1007/s00011-007-7136-9Search in Google Scholar PubMed

88. Pelclová D, Fenclová Z, Syslová K, Vlčková S, Lebedová J, Pecha O, et al. Oxidative stress markers in exhaled breath condensate in lung fibroses are not significantly affected by systemic diseases. Ind Health 2011;49:746–54.10.2486/indhealth.MS1237Search in Google Scholar PubMed

89. Stolarek R, Potargowicz E, Seklewska E, Jakubik J, Lewandowski M, Jeziorski A, et al. Increased H2O2 level in exhaled breath condensate in primary breast cancer patients. J Cancer Res Clin Oncol 2010;136:923–30.10.1007/s00432-009-0734-xSearch in Google Scholar PubMed

90. Rysz J, Kasielski M, Apanasiewicz J, Król M, Woźnicki A, Luciak M, et al. Increased hydrogen peroxide in the exhaled breath of uraemic patients unaffected by haemodialysis. Nephrol Dial Transplant 2004;19:158–63.10.1093/ndt/gfg499Search in Google Scholar PubMed

91. Rysz J, Stolarek RA, Pedzik A, Fijalkowska J, Luczynska M, Sarniak A, et al. Increased exhaled H2O2 and impaired lung function in patients undergoing bioincompatible hemodialysis. Int J Artif Organs 2007;30:879–88.10.1177/039139880703001004Search in Google Scholar PubMed

92. Teng Y, Sun P, Zhang J, Yu R, Bai J, Yao X, et al. Hydrogen peroxide in exhaled breath condensate in patients with asthma: a promising new biomarker? Chest 2011;140:108–16.10.1378/chest.10-2816Search in Google Scholar PubMed

93. Ueno T, Kataoka M, Hirano A, Iio K, Tanimoto Y, Kanehiro A, et al. Inflammatory markers in exhaled breath condensate from patients with asthma. Respirology 2008;13:654–63.10.1111/j.1440-1843.2008.01315.xSearch in Google Scholar PubMed

94. Nightingale JA, Rogers DF, Chung KF, Barnes PJ. No effect of inhaled budesonide on the response to inhaled ozone in normal subjects. Am J Respir Crit Care Med 2000;161: 479–86.10.1164/ajrccm.161.2.9905031Search in Google Scholar PubMed

95. Szkudlarek U, Zdziechowski A, Witkowski K, Kasielski M, Luczyńska M, Luczyński R, et al. Effect of inhaled N-acetylcysteine on hydrogen peroxide exhalation in healthy subjects. Pulm Pharmacol Ther 2004;17:155–62.10.1016/j.pupt.2004.01.007Search in Google Scholar PubMed

96. Rysz J, Stolarek RA, Luczynski R, Sarniak A, Wlodarczyk A, Kasielski M, et al. Increased hydrogen peroxide concentration in the exhaled breath condensate of stable COPD patients after nebulized N-acetylcysteine. Pulm Pharmacol Ther 2007;20:281–9.10.1016/j.pupt.2006.03.011Search in Google Scholar PubMed

97. De Benedetto F, Aceto A, Dragani B, Spacone A, Formisano S, Pela R, et al. Long-term oral N-acetylcysteine reduces exhaled hydrogen peroxide in stable COPD. Pulm Pharmacol Ther 2005;18:41–7.10.1016/j.pupt.2004.09.030Search in Google Scholar PubMed

98. Vass G, Huszár E, Barát E, Valyon M, Kiss D, Pénzes I, et al. Comparison of nasal and oral inhalation during exhaled breath condensate collection. Am J Respir Crit Care Med 2003;167:850–5.10.1164/rccm.200207-716BCSearch in Google Scholar PubMed

99. Zetterquist W, Marteus H, Kalm-Stephens P, Näs E, Nordvall L, Johannesson M, et al. Oral bacteria, the missing link to ambiguous findings of exhaled nitrogen oxides in cystic fibrosis. Respir Med 2009;103:187–93.10.1016/j.rmed.2008.09.009Search in Google Scholar PubMed

100. Motta A, Paris D, Melck D, de Laurentiis G, Maniscalco M, Sofia M, et al. Nuclear magnetic resonance-based metabolomics of exhaled breath condensate: methodological aspects. Eur Respir J 2012;39:498–500.10.1183/09031936.00036411Search in Google Scholar PubMed

101. Sofia M, Maniscalco M, de Laurentiis G, Paris D, Melck D, Motta A. Exploring airway diseases by NMR-based metabonomics: a review of application to exhaled breath condensate. J Biomed Biotechnol 2011;2011:1–7.10.1155/2011/403260Search in Google Scholar PubMed PubMed Central

102. Ichikawa T, Matsunaga K, Minakata Y, Yanagisawa S, Ueshima K, Akamatsu K, et al. Possible impact of salivary influence on cytokine analysis in exhaled breath condensate. Anal Chem Insights 2007;2:85–92.10.4137/117739010700200007Search in Google Scholar

103. Griese M, Noss J, von Bredow C. Protein pattern of exhaled breath condensate and saliva. Proteomics 2002;2:690–6.10.1002/1615-9861(200206)2:6<690::AID-PROT690>3.0.CO;2-6Search in Google Scholar

104. de Laurentiis G, Paris D, Melck D, Maniscalco M, Marsico S, Corso G, et al. Metabonomic analysis of exhaled breath condensate in adults by nuclear magnetic resonance spectroscopy. Eur Respir J 2008;32:1175–83.10.1183/09031936.00072408Search in Google Scholar

105. Franklin P, Moeller A, Hall GL, Horak FJ, Patterson H, Stick SM. Variability of nitric oxide metabolites in exhaled breath condensate. Respir Med 2006;100:123–9.10.1016/j.rmed.2005.03.033Search in Google Scholar

106. Carraro S, Rezzi S, Reniero F, Héberger K, Giordano G, Zanconato S, et al. Metabolomics applied to exhaled breath condensate in childhood asthma. Am J Respir Crit Care Med 2007;175:986–90.10.1164/rccm.200606-769OCSearch in Google Scholar

107. Montuschi P, Paris D, Melck D, Lucidi V, Ciabattoni G, Raia V, et al. NMR spectroscopy metabolomic profiling of exhaled breath condensate in patients with stable and unstable cystic fibrosis. Thorax 2012;67:222–8.10.1136/thoraxjnl-2011-200072Search in Google Scholar

108. Izquierdo-García JL, Peces-Barba G, Heili S, Diaz R, Want E, Ruiz-Cabello J. Is NMR-based metabolomic analysis of exhaled breath condensate accurate? Eur Respir J 2011;37:468–70.10.1183/09031936.00094010Search in Google Scholar

109. Effros RM. Metabolomics in exhaled breath condensates. Am J Respir Crit Care Med 2008;177:236.10.1164/ajrccm.177.2.236Search in Google Scholar

110. Dekhuijzen PN, Aben KK, Dekker I, Aarts LP, Wielders PL, van Herwaarden CL, et al. Increased exhalation of hydrogen peroxide in patients with stable and unstable chronic obstructive pulmonary disease. Am J Respir Crit Care Med 1996;154:813–6.10.1164/ajrccm.154.3.8810624Search in Google Scholar

111. Loukides S, Horváth I, Wodehouse T, Cole PJ, Barnes PJ. Elevated levels of expired breath hydrogen peroxide in bronchiectasis. Am J Respir Crit Care Med 1998;158:991–4.10.1164/ajrccm.158.3.9710031Search in Google Scholar

112. Kietzmann D, Kahl R, Müller M, Burchardi H, Kettler D. Hydrogen peroxide in expired breath condensate of patients with acute respiratory failure and with ARDS. Intensive Care Med 1993;19:78–81.10.1007/BF01708366Search in Google Scholar

113. Luczynska M, Szkudlarek U, Dziankowska-Bartkowiak B, Waszczykowska W, Kasielski M, Sysa-Jedrzejowska A, et al. Elevated exhalation of hydrogen peroxide in patients with systemic sclerosis. Eur J Clin Invest 2003;33:274–9.10.1046/j.1365-2362.2003.01138.xSearch in Google Scholar

114. Moloney ED, Mumby SE, Gajdocsi R, Cranshaw JH, Kharitonov SA, Quinlan GJ, et al. Exhaled breath condensate detects markers of pulmonary inflammation after cardiothoracic surgery. Am J Respir Crit Care Med 2004;169:64–9.10.1164/rccm.200307-1005OCSearch in Google Scholar

115. Jöbsis Q, Raatgeep HC, Schellekens SL, Kroesbergen A, Hop WC, de Jongste JC. Hydrogen peroxide and nitric oxide in exhaled air of children with cystic fibrosis during antibiotic treatment. Eur Respir J 2000;16:95–100.10.1034/j.1399-3003.2000.16a17.xSearch in Google Scholar

116. Brooks WM, Lash H, Kettle AJ, Epton MJ. Optimising hydrogen peroxide measurement in exhaled breath condensate. Redox Rep 2006;11:78–84.10.1179/135100006X101011Search in Google Scholar

117. Loukides S, Kontogianni K, Hillas G, Horváth I. Exhaled breath condensate in asthma: from bench to bedside. Curr Med Chem 2011;18:1432–43.10.2174/092986711795328418Search in Google Scholar

118. van Hoydonck PG, Wuyts WA, Vanaudenaerde BM, Schouten EG, Dupont LJ, Temme EH. Quantitative analysis of 8-isoprostane and hydrogen peroxide in exhaled breath condensate. Eur Respir J 2004;23:189–92.10.1183/09031936.03.00049403Search in Google Scholar

119. Svensson S, Olin AC, Lärstad M, Ljungkvist G, Torén K. Determination of hydrogen peroxide in exhaled breath condensate by flow injection analysis with fluorescence detection. J Chromatogr B Analyt Technol Biomed Life Sci 2004;809:199–203.10.1016/S1570-0232(04)00513-6Search in Google Scholar

120. Hu Y, Zhang Z, Yang C. A sensitive chemiluminescence method for the determination of H2O2 in exhaled breath condensate. Anal Sci 2008;24:201–5.10.2116/analsci.24.201Search in Google Scholar PubMed

121. Gerritsen WB, Zanen P, Bauwens AA, van den Bosch JM, Haas FJ. Validation of a new method to measure hydrogen peroxide in exhaled breath condensate. Respir Med 2005;99:1132–7.10.1016/j.rmed.2005.02.020Search in Google Scholar PubMed

122. Montuschi P, Ragazzoni E, Valente S, Corbo G, Mondino C, Ciappi G, et al. Validation of 8-isoprostane and prostaglandin E2 measurements in exhaled breath condensate. Inflamm Res 2003;52:502–7.10.1007/s00011-003-1212-6Search in Google Scholar PubMed

123. Montuschi P. LC/MS/MS analysis of leukotriene B4 and other eicosanoids in exhaled breath condensate for assessing lung inflammation. J Chromatogr B 2009;877:1272–80.10.1016/j.jchromb.2009.01.036Search in Google Scholar PubMed

124. Montuschi P, Martello S, Felli M, Mondino C, Chiarotti M. Ion trap liquid chromatography/tandem mass spectrometry analysis of leukotriene B4 in exhaled breath condensate. Rapid Commun Mass Spectrom 2004;18:2723–9.10.1002/rcm.1682Search in Google Scholar PubMed

125. Hanazawa T, Kharitonov SA, Barnes PJ. Increased nitrotyrosine in exhaled breath condensate of patients with asthma. Am J Respir Crit Care Med 2000;162:1273–6.10.1164/ajrccm.162.4.9912064Search in Google Scholar PubMed

126. Cáp P, Chládek J, Pehal F, Malý M, Petrů V, Barnes PJ, et al. Gas chromatography/mass spectrometry analysis of exhaled leukotrienes in asthmatic patients. Thorax 2004;59:465–70.10.1136/thx.2003.011866Search in Google Scholar PubMed PubMed Central

127. Montuschi P, Kharitonov SA, Ciabattoni G, Barnes PJ. Exhaled leukotrienes and prostaglandins in COPD. Thorax 2003;58:585–8.10.1136/thorax.58.7.585Search in Google Scholar PubMed PubMed Central

128. Carpagnano GE, Barnes PJ, Geddes DM, Hodson ME, Kharitonov SA. Increased leukotriene B4 and interleukin-6 in exhaled breath condensate in cystic fibrosis. Am J Respir Crit Care Med 2003;167:1109–12.10.1164/rccm.200203-179OCSearch in Google Scholar PubMed

129. Antczaka A, Kharitonovb SA, Montuschib P, Gorskia P, Barnesb PJ. Inflammatory response to sputum induction measured by exhaled markers. Respiration 2005;72:594–9.10.1159/000086721Search in Google Scholar PubMed

130. Mondino C, Ciabattoni G, Koch P, Pistelli R, Trové A, Barnes PJ, et al. Effects of inhaled corticosteroids on exhaled leukotrienes and prostanoids in asthmatic children. J Allergy Clin Immunol 2004;114:761–7.10.1016/j.jaci.2004.06.054Search in Google Scholar PubMed

131. Montuschi P, Mondino C, Koch P, Barnes PJ, Ciabattoni G. Effects of a leukotriene receptor antagonist on exhaled leukotriene E4 and prostanoids in children with asthma. J Allergy Clin Immunol 2006;118:347–53.10.1016/j.jaci.2006.04.010Search in Google Scholar PubMed

132. Montuschi P, Martello S, Felli M, Mondino C, Barnes PJ, Chiarotti M. Liquid chromatography/mass spectrometry analysis of exhaled leukotriene B4 in asthmatic children. Respir Res 2005;6:119–26.10.1186/1465-9921-6-119Search in Google Scholar PubMed PubMed Central

133. Profita M, Montuschi P, Bonanno A, Riccobono L, Montalbano AM, Ciabattoni G, et al. Novel perspectives in the detection of oral and nasal oxidative stress and inflammation in pediatric united airway diseases. Int J Immunopathol Pharmacol 2010;23:1211–9.10.1177/039463201002300425Search in Google Scholar

134. Montuschi P, Currò D, Ragazzoni E, Preziosi P, Ciabattoni G. Anaphylaxis increases 8-iso-prostaglandin F2α release from guinea-pig lung in vitro. Eur J Pharmacol 1999;365:59–64.10.1016/S0014-2999(98)00859-0Search in Google Scholar

135. Antczak A, Montuschi P, Kharitonov S, Gorski P, Barnes PJ. Increased exhaled cysteinyl-leukotrienes and 8-isoprostane in aspirin-induced asthma. Am J Respir Crit Care Med 2002;166:301–6.10.1164/rccm.2101021Search in Google Scholar PubMed

136. Biernacki WA, Kharitonov SA, Barnes PJ. Increased leukotriene B4 and 8-isoprostane in exhaled breath condensate of patients with exacerbations of COPD. Thorax 2003;58:294–8.10.1136/thorax.58.4.294Search in Google Scholar PubMed PubMed Central

137. Carpenter CT, Price PV, Christman BW. Exhaled breath condensate isoprostanes are elevated in patients with acute lung injury or ARDS. Chest 1998;114:1653–9.10.1378/chest.114.6.1653Search in Google Scholar PubMed

138. Montuschi P, Kharitonov SA, Ciabattoni G, Corradi M, van Rensen L, Geddes DM, et al. Exhaled 8-isoprostane as a new non-invasive biomarker of oxidative stress in cystic fibrosis. Thorax 2000;55:205–9.10.1136/thorax.55.3.205Search in Google Scholar PubMed PubMed Central

139. Lucidi V, Ciabattoni G, Bella S, Barnes PJ, Montuschi P. Exhaled 8-isoprostane and prostaglandin E2 in patients with stable and unstable cystic fibrosis. Free Radical Biol Med 2008;45:913–9.10.1016/j.freeradbiomed.2008.06.026Search in Google Scholar PubMed

140. Barreto M, Villa MP, Olita C, Martella S, Ciabattoni G, Montuschi P. 8-Isoprostane in exhaled breath condensate and exercise-induced bronchoconstriction in asthmatic children and adolescents. Chest 2009;135:66–73.10.1378/chest.08-0722Search in Google Scholar PubMed

141. Kharitonov SA, Barnes PJ. Biomarkers of some pulmonary diseases in exhaled breath. Biomarkers 2002;7:1–32.10.1080/13547500110104233Search in Google Scholar PubMed

142. Reiter CD, Teng RJ, Beckman JS. Superoxide reacts with nitric oxide to nitrate tyrosine at physiological pH via peroxynitrite. J Biol Chem 2000;275:32460–6.10.1074/jbc.M910433199Search in Google Scholar PubMed

143. Liu J, Thomas PS. Exhaled breath condensate as a method of sampling airway nitric oxide and other markers of inflammation. Med Sci Monit 2005;11:MT53–62.Search in Google Scholar

144. Lee W, Thomas PS. Oxidative stress in COPD and its measurement through exhaled breath condensate. Clin Transl Sci 2009;2:150–5.10.1111/j.1752-8062.2009.00093.xSearch in Google Scholar

145. Chow S, Thomas PS, Malouf M, Yates DH. Exhaled breath condensate (EBC) biomarkers in pulmonary fibrosis. J Breath Res 2012;6:016004.10.1088/1752-7155/6/1/016004Search in Google Scholar

146. Robroeks CM, Rosias PP, van Vliet D, Jöbsis Q, Yntema JB, Brackel HJ, et al. Biomarkers in exhaled breath condensate indicate presence and severity of cystic fibrosis in children. Pediatr Allergy Immunol 2008;19:652–9.10.1111/j.1399-3038.2007.00693.xSearch in Google Scholar

147. Gessner C, Hammerschmidt S, Kuhn H, Lange T, Engelmann L, Schauer J, et al. Exhaled breath condensate nitrite and its relation to tidal volume in acute lung injury. Chest 2003;124:1046–52.10.1378/chest.124.3.1046Search in Google Scholar

148. Csoma Z, Bush A, Wilson NM, Donnelly L, Balint B, Barnes PJ, et al. Nitric oxide metabolites are not reduced in exhaled breath condensate of patients with primary ciliary dyskinesia. Chest 2003;124:633–8.10.1378/chest.124.2.633Search in Google Scholar

149. Corradi M, Pesci A, Casana R, Alinovi R, Goldoni M, Vettori MV, et al. Nitrate in exhaled breath condensate of patients with different airway diseases. Nitric Oxide 2003;8:26–30.10.1016/S1089-8603(02)00128-3Search in Google Scholar

150. Balint B, Kharitonov SA, Hanazawa T, Donnelly LE, Shah PL, Hodson ME, et al. Increased nitrotyrosine in exhaled breath condensate in cystic fibrosis. Eur Respir J 2001;17:1201–7.10.1183/09031936.01.00072501Search in Google Scholar PubMed

151. Celio S, Troxler H, Durka SS, Chládek J, Wildhaber JH, Sennhauser FH, et al. Free 3-nitrotyrosine in exhaled breath condensates of children fails as a marker for oxidative stress in stable cystic fibrosis and asthma. Nitric Oxide 2006;15: 226–32.10.1016/j.niox.2006.06.008Search in Google Scholar PubMed

152. Donnelly L. Exhaled breath condensate: nitric oxide-related compounds. In: Horváth I, de Jongste JC, editors. European Respiratory Monograph (Exhaled Biomarkers). Plymouth: Latimer Trend & Co, 2010:207–16.Search in Google Scholar

153. Fang K, Ragsdale NV, Carey RM, MacDonald T, Gaston B. Reductive assays for S-nitrosothiols: implications for measurements in biological systems. Biochem Biophys Res Commun 1998;252:535–40.10.1006/bbrc.1998.9688Search in Google Scholar PubMed

154. Vogelberg C, Kahlert A, Würfel C, Marx K, Böhm A, Range U, et al. Exhaled breath condensate nitrite – methodological problems of sample collection. Med Sci Monit 2008;14: CR416–22.Search in Google Scholar

155. Hom S, Walsh B, Hunt J. Matrix effect in exhaled breath condensate interferon-gamma immunoassay. J Breath Res 2008;2:041001.10.1088/1752-7155/2/4/041001Search in Google Scholar PubMed

156. Ahmadzai H, Wakefield D, Thomas PS. The potential of the immunological markers of sarcoidosis in exhaled breath and peripheral blood as future diagnostic and monitoring techniques. Inflammopharmacology 2011;19:55–68.10.1007/s10787-011-0079-3Search in Google Scholar

157. Robroeks CM, van de Kant KD, Jöbsis Q, Hendriks HJ, van Gent R, Wouters EF, et al. Exhaled nitric oxide and biomarkers in exhaled breath condensate indicate the presence, severity and control of childhood asthma. Clin Exp Allergy 2007;37:1303–11.10.1111/j.1365-2222.2007.02788.xSearch in Google Scholar

158. Nowak D, Kasielski M, Antczak A, Pietras T, Bialasiewicz P. Increased content of thiobarbituric acid-reactive substances and hydrogen peroxide in the expired breath condensate of patients with stable chronic obstructive pulmonary disease: no significant effect of cigarette smoking. Respir Med 1999;93:389–96.10.1053/rmed.1999.0574Search in Google Scholar

159. Corradi M, Alinovi R, Goldoni M, Vettori M, Folesani G, Mozzoni P, et al. Biomarkers of oxidative stress after controlled human exposure to ozone. Toxicol Lett 2002;134:219–25.10.1016/S0378-4274(02)00169-8Search in Google Scholar

160. Celik M, Tuncer A, Soyer OU, Saçkesen C, Tanju Besler H, Kalayci O. Oxidative stress in the airways of children with asthma and allergic rhinitis. Pediatr Allergy Immunol 2012;23:556–61.10.1111/j.1399-3038.2012.01294.xSearch in Google Scholar PubMed

161. Manini P, Andreoli R, Sforza S, Dall’Asta C, Galaverna G, Mutti A, et al. Evaluation of alternate isotope-coded derivatization assay (AIDA) in the LC-MS/MS analysis of aldehydes in exhaled breath condensate. J Chromatogr B Analyt Technol Biomed Life Sci 2010;878:2616–22.10.1016/j.jchromb.2010.02.010Search in Google Scholar PubMed

162. Esther CR, Boysen G, Olsen BM, Collins LB, Ghio AJ, Swenberg JW, et al. Mass spectrometric analysis of biomarkers and dilution markers in exhaled breath condensate reveals elevated purines in asthma and cystic fibrosis. Am J Physiol Lung Cell Mol Physiol 2009;296:L987–93.10.1152/ajplung.90512.2008Search in Google Scholar PubMed PubMed Central

163. Vass G, Huszár E, Augusztinovicz M, Baktai G, Barát E, Herjavecz I, et al. The effect of allergic rhinitis on adenosine concentration in exhaled breath condensate. Clin Exp Allergy 2006;36:742–7.10.1111/j.1365-2222.2006.02496.xSearch in Google Scholar PubMed

164. Lázár Z, Vass G, Huszár E, Losonczy G, Horváth I. Exhaled breath condensate: adenosine, ATP and other purines. In: Horváth I, de Jongste JC, editors. European Respiratory Monograph (Exhaled Biomarkers). Plymouth: Latimer Trend and Co, 2010:183–95.Search in Google Scholar

165. Huszar E, Barat E, Kollai M. Isocratic high-performance liquid chromatographic determination of plasma adenosine. Chromatographia 1996;42:318–22.10.1007/BF02290317Search in Google Scholar

166. Pryor WA, Stone K. Oxidants in cigarette smoke. Radicals, hydrogen peroxide, peroxynitrate, and peroxynitrite. Ann NY Acad Sci 1993;686:12–27.10.1111/j.1749-6632.1993.tb39148.xSearch in Google Scholar PubMed

167. Makris D, Paraskakis E, Korakas P, Karagiannakis E, Sourvinos G, Siafakas NM, et al. Exhaled breath condensate 8-isoprostane, clinical parameters, radiological indices and airway inflammation in COPD. Respiration 2008;72:138–44.10.1159/000106377Search in Google Scholar PubMed

168. Montuschi P, Kharitonov SA, Barnes PJ. Exhaled carbon monoxide and nitric oxide in COPD. Chest 2001;120: 496–501.10.1378/chest.120.2.496Search in Google Scholar PubMed

169. Scheideler L, Manke HG, Schwulera U, Inacker O, Hammerle H. Detection of nonvolatile macromolecules in breath. A possible diagnostic tool? Am Rev Respir Dis 1993;148:778–84.10.1164/ajrccm/148.3.778Search in Google Scholar PubMed

170. Horváth I, Lázár Z, Gyulai N, Kollai M, Losonczy G. Exhaled biomarkers in lung cancer. Eur Respir J 2009;34:261–75.10.1183/09031936.00142508Search in Google Scholar PubMed

171. Chan H, Lewis C, Thomas PS. Exhaled breath analysis: novel approach for early detection of lung cancer. Lung Cancer 2009;63:164–8.10.1016/j.lungcan.2008.05.020Search in Google Scholar PubMed

172. Chan H, Lewis C, Thomas PS. Oxidative stress and exhaled breath analysis: a promising tool for detection of lung cancer. Cancers 2010;2:32–42.10.3390/cancers2010032Search in Google Scholar PubMed PubMed Central

173. Carpagnano G, Foschino-Barbaro MP, Mulé G, Resta O, Tommasi S, Mangia A, et al. 3p microsatellite alterations in exhaled breath condensate from patients with non-small cell lung cancer. Am J Respir Crit Care Med 2005;172:738–44.10.1164/rccm.200503-439OCSearch in Google Scholar PubMed

174. Carpagnano G, Foschino-Barbaro MP, Spanevello A, Resta O, Carpagnano F, Mulé G, et al. 3p microsatellite signature in exhaled breath condensate and tumor tissue of patients with lung cancer. Am J Respir Crit Care Med 2008;177:337–41.10.1164/rccm.200707-1136OCSearch in Google Scholar PubMed

175. Gessner C, Kuhn H, Toepfer K, Hammerschmidt S, Schauer J, Wirtz H. Detection of p53 gene mutations in exhaled breath condensate of non-small cell lung cancer patients. Lung Cancer 2004;43:215–22.10.1016/j.lungcan.2003.08.034Search in Google Scholar PubMed

176. Kordiak J, Szemraj J, Hamara K, Bialasiewicz P, Nowak D. Complete surgical resection of lung tumor decreases exhalation of mutated KRAS oncogene. Respir Med 2012;106:1293–300.10.1016/j.rmed.2012.06.019Search in Google Scholar PubMed

177. Zhang D, Takigawa N, Ochi N, Tanimoto Y, Noujima D, Chen YY, et al. Detection of the EGFR mutation in exhaled breath condensate from a heavy smoker with squamous cell carcinoma of the lung. Lung Cancer 2011;73:379–80.10.1016/j.lungcan.2011.05.018Search in Google Scholar PubMed

178. Han W, Wang T, Reilly AA, Keller SM, Spivack SD. Gene promoter methylation assayed in exhaled breath, with differences in smokers and lung cancer patients. Respir Res 2009;10:86–97.10.1186/1465-9921-10-86Search in Google Scholar PubMed PubMed Central

179. Carpagnano G, Koutelou A, Natalicchio MI, Martinelli D, Ruggieri C, Di Taranto A, et al. HPV in exhaled breath condensate of lung cancer patients. Br J Cancer 2011;105: 1183–90.10.1038/bjc.2011.354Search in Google Scholar PubMed PubMed Central

180. Xu Z, Shen F, Li X, Wu Y, Chen Q, Jie X, et al. Molecular and microscopic analysis of bacteria and viruses in exhaled breath collected using a simple impaction and condensing method. PLoS One 2012;7:e41137.10.1371/journal.pone.0041137Search in Google Scholar PubMed PubMed Central

181. Zakharkina T, Koczulla AR, Mardanova O, Hattesohl A, Bals R. Detection of microorganisms in exhaled breath condensate during acute exacerbations of COPD. Respirology 2011;16:932–8.10.1111/j.1440-1843.2011.01977.xSearch in Google Scholar PubMed

182. Jain R, Schriever CA, Danziger LH, Cho SH, Rubinstein I. The IS6110 repetitive DNA element of Mycobacterium tuberculosis is not detected in exhaled breath condensate of patients with active pulmonary tuberculosis. Respiration 2007;74:329–33.10.1159/000101786Search in Google Scholar PubMed

183. Schreiber J, Meyer C, Rüsch-Gerdes S, Richter E, Beck H, Fischer JF, et al. Mycobacterium tuberculosis gene-amplification in breath condensate of patients with lung tuberculosis. Eur J Med Res 2002;7:290–1.Search in Google Scholar

184. Vogelberg C, Hirsch T, Rösen-Wolff A, Kerkmann ML, Leupold W. Pseudomonas aeruginosa and Burkholderia cepacia cannot be detected by PCR in the breath condensate of patients with cystic fibrosis. Pediatr Pulmonol 2003;36:348–52.10.1002/ppul.10352Search in Google Scholar PubMed

Received: 2012-9-11
Accepted: 2013-1-28
Published Online: 2013-02-18
Published in Print: 2013-07-01

©2013 by Walter de Gruyter Berlin Boston