Skip to main content

Absolute volume of the rectum and AUC from rectal DVH between 25Gy and 50Gy predict acute gastrointestinal toxicity with IG-IMRT in prostate cancer

Abstract

Background

To determine whether dose/volume specific endpoints (DVSE) or Area under the rectal DVH curve (rAUC) better predict acute gastrointestinal (GI) toxicity in prostate cancer patients treated with IMRT in the era of daily image guidance (IG-IMRT).

Methods

A set of DVSE was recorded from V25 to V75 (increments of 5Gy) (both in % and in cc) for 180 men. The rAUC was calculated for doses ranging between 25Gy and 50Gy (rAUC25–50). Univariate and multivariate logistic regressions were performed to determine the relationship between DVSE or rAUC25–50 and the appearance of any acute GI toxicity.

Results

The rates of acute grade 1 (G1), G2 and G3 GI toxicities were 53.3 %, 10.6 % and 1.1 %, respectively. No G4+ toxicity was observed.

Rectal V25 to V75 expressed in % were not predictive of G ≥ 1 GI toxicity (p ≥ 0.12) whereas rectal V25 to V50 expressed in cc did correlate with GI toxicity G ≥ 1 (p ≤ 0.04). rAUC25–50 expressed in cc. Gy correlated significantly with the occurrence of any acute GI toxicity G ≥ 1 (p = 0.027).

Conclusions

The absolute volume of the rectum between 25Gy and 50Gy and rAUC25–50 could significantly predict any acute rectal toxicity in prostate cancer patients treated with daily IG-IMRT.

Background

Intensity Modulated Radiation Therapy (IMRT) with daily image guidance of soft tissues in patients with localized prostate cancer (PCa) has been shown to improve biochemical control and to reduce rectal toxicities compared with 3-dimensional conformal radiation therapy (3D-CRT) [13]. The risk of normal tissue complications is typically evaluated from the amount of tissue exposed to a given dose (namely, dose-volume specific endpoint (DVSE)). For 3D-CRT, DVSE have been demonstrated to be reliable and reproducible for predicting acute and late toxicity according to Radiation Therapy Oncology Group (RTOG) scoring criteria [4]. Several dose-constraint guidelines, based on post-hoc analyses of rectal toxicity and its correlation with each DVSE, have been established to determine what relative volume of rectum (in %) can safely receive high doses [58].

As for image-guided IMRT (IG-IMRT), there are no robust, reproducible data in the literature to indicate which DVSE are useful for a more accurate prediction of acute toxicity. Guidelines used by radiation clinicians were based on late toxicities and came mostly from 3D conformal radiotherapy [4]. Regarding the lower rates of rectal toxicity observed with IG-IMRT compared with 3D-CRT [9], standard DVSE developed from 3D-CRT results could be irrelevant. Hence, new tools are needed for IG-IMRT to improve predictions for any grade of acute toxicity. The purpose of this study was to determine a new type of dose/volume parameter to predict any acute GI toxicity with daily IG-IMRT. This new parameter was determined by studying a set of several DVSE expressed in % and in cc. As the shape of the entire rectal DVH curve from low to high doses cannot be reflected by one single DVSE or even several DVSE, we also investigated the area under the rectum DVH curve (rAUC) as a challenger for predicting acute GI toxicity.

Methods

Selection of patients

We selected 180 men with at least eight visits for toxicity evaluations and with available DVH data. All of the men had localized PCa treated with daily IG-IMRT with curative intent.

Characteristics of patients are summarized in Table 1.

Table 1 Characteristics of patients and treatments

IMRT

All patients first underwent a planning CT scan with 2.5 mm slice thickness in the supine position with knee and ankle supports. A rectal enema was given before the CT for each patient. They were asked to maintain the same degree of bladder filling during the simulation and treatment sessions. Critical normal-tissue structures were outlined by a radiation oncologist on each axial CT image. The rectum was defined as a cylindrical structure around the outer rectal wall and contoured from the ischial tuberosities to the rectosigmoid junction, identified in accordance with international guidelines by the level at which the GI tract narrows and diverges anteriorly from the rectum [4, 10].

Intensity was modulated by dynamic multileaf collimation using the sliding window technique, as previously described by our group in this journal [10, 11]. Patients who underwent whole pelvic radiotherapy were excluded from this study. The median dose prescribed to the prostate PTV was 78Gy [74–80] at 2Gy per fraction and five fractions per week.

IGRT

Daily on-line repositioning based on soft-tissues was performed for all the patients using either kV Cone Beam Computed Tomography or a 3D ultrasound system as described in detail elsewhere [11, 12].

Dose/volume modeling for rectal toxicity

A set of standard DVSEs was tested: the volume of the rectum receiving from 25Gy to 75Gy (V25 to V75), expressed in percentages (%) and in cubic centimeters (cc).

Calculation of the area under the rectum DVH curve (rAUC)

In the second step, we calculated the area under the DVH curve between 25 and 50Gy for the rectum (rAUC25–50).

The respective rAUC, expressed in cc.Gy, were calculated every 5Gy in the following manner (Fig. 1):

Fig. 1
figure 1

Illustration of rAUC 5Gy calculation from 25 to 30Gy (rAUC25–30). Legends: DVH: Dose Volume Histogram, V25 = volume of rectum receiving 25Gy; V30 = volume of rectum receiving 30Gy; rAUC25–30 = Area Under the Curve of rectal DHV between 25 and 30Gy

$$ {\mathrm{rAUC}}_{\mathrm{doseX}\hbox{-} \mathrm{X}+5\mathrm{Gy}=}5*{\mathrm{V}}_{\mathrm{X}+5\mathrm{Gy}} + 2.5*\left({\mathrm{V}}_{\mathrm{X}\mathrm{Gy}}\hbox{-} {\mathrm{V}}_{\mathrm{X}+5\mathrm{Gy}}\right) $$

For example (Fig. 1): rAUC25 ‐ 30 = 5 * V30 + 2.5 * (V25 ‐ V30)

Thus, rAUC25 ‐ 50 = rAUC25 ‐ 30 + rAUC30 ‐ 35 + rAUC35 ‐ 40 + rAUC40 ‐ 45 + rAUC45 ‐ 50

Follow-up and toxicity evaluation

Each patient was seen in our institution every week during the radiation therapy and at 3 months and 6 months thereafter. Acute toxicity was evaluated and scored using the Common Toxicity Criteria Adverse Events scales (CTCAE) version 3.0 weekly during each week of radiotherapy and 3 months after the completion of the radiotherapy. As acute toxicities can last for 3 months, we chose to extend our evaluation to 6 months. The worse GI toxicity (diarrhea, constipation, hemorrhoids, rectal hemorrhage, anal incontinence, proctitis and anitis) grade of each patient was analyzed.

Statistical analyses

Mann–Whitney tests were used to determine the relationship between V25-V75, expressed in % and in cc or rAUC25–50 and the appearance of any acute GI toxicity (G ≥ 1).

The optimal rAUC25–50 cut-off value related to acute GI toxicity was determined using a ROC curve with Youden’s index. Univariate and multivariate logistic regressions were used to describe the acute GI toxicity (G ≥ 1) by estimating the Odds-Ratio and 95 % confidence interval (CI). The multivariate model included the optimal rAUC25–50 cut-off value and the adjustment parameters (age, transurethral resection of the prostate (TURP), hormone therapy and rectum volume). The multivariate model was internally validated using bootstrapping (170 replications).

All analyses were performed using Stata V13 software (StataCorp LP, College Station, TX). P values were two-tailed and considered significant when less than 0.05.

Results

Characterization of toxicity

We observed acute G1, G2 and G3 GI toxicity in 96 patients (53.3 %), 19 patients (10.6 %) and 2 patients (1.1 %), respectively. No G4 or G5 GI toxicity was observed. Among these toxicities, 35.8 % of patients had diarrhea (29.6 % G1 and 6.2 % G2) and 36.1 % of patients had proctitis (32.2 % G1, 3.3 % G2 and 0.6 % G3).

Predictors of acute GI toxicity

The median volumes of the rectum in % and in cc receiving from 25Gy to 75Gy (increments of 5Gy) are presented in Table 2.

Table 2 Evaluation of relationship between DVSE and acute gastrointestinal toxicity using univariate logistic regression analysis

In the univariate analysis of the entire patient population, we found no relationship between any rectal volume parameters expressed in % and any acute GI toxicity ≥ grade1 (p from 0.12 to 0.92) (Table 2).

Conversely, when expressed in cc, all rectal volumes from V25 to V50 correlated significantly with acute GI toxicity G ≥ 1 (p from 0.018 to 0.045). Beyond 50Gy, no relationship was found between the volume of rectum expressed in cc and acute GI toxicity (from 55Gy to 75Gy, p-values ranged between 0.069 and 0.853) (Table 2).

The rAUC25–50 calculated using the rectum volume expressed in cc correlated with any grade ≥1 acute GI toxicity (p = 0.028) (Table 2) while the rAUC25–50 calculated using rectum volume expressed in % did not correlate with any acute GI toxicity (data not shown).

Multivariate logistic regression, which included the variables age, hormone therapy, TURP and rectum volume (cc), was used. Among these variables, only rectum volume expressed in cc correlated significantly with acute GI toxicity (p = 0.041). A Liu/Youden cutting method showed that patients with a rAUC25–50 > 794 cc.Gy were more likely to develop acute GI toxicity with IG-IMRT (p = 0.020, [95 % CI: 1.16–5.46]) (Table 3). These results were validated by a bootstrapping method using 170 replications (p = 0.019; [95 % CI: 1.16–5.42]).

Table 3 Optimal rAUC25–50 cut-off value related to acute GI toxicity Grade ≥ 1 determined using a ROC curve (multivariate logistic regression)

Discussion

One of the major limits of DVSE is that the DVH curve can reach V70 by different paths, meaning that doses delivered before or beyond this specific endpoint might differ considerably for the same V70. Given this, for the same volume of rectum receiving a high dose, one patient may have a greater rectal volume irradiated at lower doses while another may have his rectum spared when evaluated according to the planning CT. For this reason, the QUANTEC recommended several DVSE in the context of dose escalation delivered using 3D conformational radiotherapy [4]. Recently, like us, Pederson et al. found a lack of any correlation between standard DVSE criteria and late GI or GU (genitourinary) toxicities, evaluated using RTOG and CTCAE V3.0 scales, induced by IMRT [13]. The authors suggested adapting rectum DVH, which correlated with late toxicities induced by IMRT. A new parameter related to acute toxicity has yet to be developed.

A number of preliminary clinical studies on high-dose IMRT and/or high-dose IGRT, like ours, reported very low rates of acute GI toxicity. In routine practice with IG-IMRT, acute toxicity is much more frequent than late toxicity and most patients have grade 1 or 2 toxicity only, suggesting that it would be better to figure out what dose/volume parameters best predict any acute GI toxicity (n = 117 in our series) rather than severe GI toxicity only. Although acute toxicities were prospectively recorded in the follow-up of all of the patients, one limitation of our study arises from the retrospective design, with drawbacks related to the post hoc scoring of toxicity using version 3 of the CTC scale.

Even though toxicity was prospectively scored, one drawback of our retrospective analyses concerns the major differences in scoring systems in the literature. Patient-reported outcomes may be more clinically relevant and we therefore suggest conducting a new prospective study that includes both physician- and patient-reported outcomes.

Nevertheless we found a lower rate of acute G ≥ 2 GI toxicity in our series (12 %), which was very similar to that observed by Kupelian et al. in 488 patients with daily IG-IMRT (11 % of G2 acute rectal toxicity) [14] but lower than that observed by Wortel et al. in 260 patients treated with IMRT (29 % of G ≥ 2 acute rectal toxicity) [9]. These two studies used the RTOG toxicity scoring system. In another report, Singh et al. also confirmed less severe rectal symptoms with IGRT compared with non-IGRT [2].

We believe that daily IG-IMRT with a sharper dose gradient, thanks to daily repositioning on the prostate isocenter, may ensure that high doses are only delivered to the same small areas of the rectum as is the case with brachytherapy. Our results are in keeping with this hypothesis as we found that only the absolute volume of the rectum (but not the relative volume of the rectum) between 25Gy and 50Gy correlated with acute GI toxicity when patients were treated with daily on-line IG-IMRT.

Moreover, these results suggest that intermediate doses delivered to the rectum may be more relevant than high doses with daily IG-IMRT.

Conclusions

We have used a simple method to identify a new single parameter derived from the DVH, in contrast to several DVSE, that predicts acute GI toxicity: the rAUC25–50 is a user-friendly tool that can be implemented in any radiation oncology department worldwide.

We recommend that the rAUC25–50 of the entire rectum should not exceed 794 cc.Gy. This new predictive parameter for acute GI toxicity should be validated through a prospective study.

Abbreviations

3D-CRT:

3-dimensional conformal radiation therapy

CTCAE:

Common terminology criteria for adverse events

CTV:

Clinical target volume

DVH:

Dose volume histogram

DVSE:

Dose/volume specific endpoints

GI:

Gastrointestinal

GTV:

Gross tumor volume

GU:

Genito-urinary

HT:

Hormonotherapy

IG-IMRT:

Image-guidance intensity modulated radiation therapy

OAR:

Organs at risk

PCa:

Prostate cancer

PTV:

Planning target volume

rAUC:

Area under the rectal DVH curve

rAUC25–50 :

rAUC for doses ranging between 25Gy and 50Gy

RTOG:

Radiation Therapy Oncology Group

TURP:

Transurethral resection of the prostate

Vx:

Volume of rectum receiving xGy

References

  1. Kok D, Gill S, Bressel M, Byrne K, Kron T, Fox C, et al. Late toxicity and biochemical control in 554 prostate cancer patients treated with and without dose escalated image guided radiotherapy. Radiother Oncol. 2013;107(2):140–6.

    Article  PubMed  Google Scholar 

  2. Singh J, Greer PB, White MA, Parker J, Patterson J, Tang CI, et al. Treatment-related morbidity in prostate cancer: a comparison of 3-dimensional conformal radiation therapy with and without image guidance using implanted fiducial markers. Int J Radiat Oncol Biol Phys. 2013;85(4):1018–23.

    Article  PubMed  Google Scholar 

  3. Zelefsky MJ, Kollmeier M, Cox B, Fidaleo A, Sperling D, Pei X, et al. Improved clinical outcomes with high-dose image guided radiotherapy compared with non-IGRT for the treatment of clinically localized prostate cancer. Int J Radiat Oncol Biol Phys. 2012;84(1):125–9.

    Article  PubMed  Google Scholar 

  4. Michalski JM, Gay H, Jackson A, Tucker SL, Deasy JO. Radiation dose-volume effects in radiation-induced rectal injury. Int J Radiat Oncol Biol Phys. 2010;76(3 Suppl):S123–9. Pubmed Central PMCID: 3319467.

    Article  PubMed  PubMed Central  Google Scholar 

  5. Boersma LJ, van den Brink M, Bruce AM, Shouman T, Gras L, te Velde A, et al. Estimation of the incidence of late bladder and rectum complications after high-dose (70–78 GY) conformal radiotherapy for prostate cancer, using dose-volume histograms. Int J Radiat Oncol Biol Phys. 1998;41(1):83–92.

    Article  CAS  PubMed  Google Scholar 

  6. Chan LW, Xia P, Gottschalk AR, Akazawa M, Scala M, Pickett B, et al. Proposed rectal dose constraints for patients undergoing definitive whole pelvic radiotherapy for clinically localized prostate cancer. Int J Radiat Oncol Biol Phys. 2008;72(1):69–77.

    Article  PubMed  Google Scholar 

  7. Fiorino C, Valdagni R, Rancati T, Sanguineti G. Dose-volume effects for normal tissues in external radiotherapy: pelvis. Radiother Oncol. 2009;93(2):153–67.

    Article  PubMed  Google Scholar 

  8. Huang EH, Pollack A, Levy L, Starkschall G, Dong L, Rosen I, et al. Late rectal toxicity: dose-volume effects of conformal radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys. 2002;54(5):1314–21.

    Article  PubMed  Google Scholar 

  9. Wortel RC, Incrocci L, Pos FJ, Lebesque JV, Witte MG, van der Heide UA, et al. Acute toxicity after image-guided intensity modulated radiation therapy compared to 3D conformal radiation therapy in prostate cancer patients. Int J Radiat Oncol Biol Phys. 2015;91(4):737–44.

    Article  PubMed  Google Scholar 

  10. Alongi F, Fiorino C, Cozzarini C, Broggi S, Perna L, Cattaneo GM, et al. IMRT significantly reduces acute toxicity of whole-pelvis irradiation in patients treated with post-operative adjuvant or salvage radiotherapy after radical prostatectomy. Radiother Oncol. 2009;93(2):207–12.

    Article  PubMed  Google Scholar 

  11. Crehange G, Mirjolet C, Gauthier M, Martin E, Truc G, Peignaux-Casasnovas K, et al. Clinical impact of margin reduction on late toxicity and short-term biochemical control for patients treated with daily on-line image guided IMRT for prostate cancer. Radiother Oncol. 2012;103(2):244–6.

    Article  PubMed  Google Scholar 

  12. Peignaux K, Truc G, Barillot I, Ammor A, Naudy S, Crehange G, et al. Clinical assessment of the use of the Sonarray system for daily prostate localization. Radiother Oncol. 2006;81(2):176–8.

    Article  PubMed  Google Scholar 

  13. Pederson AW, Fricano J, Correa D, Pelizzari CA, Liauw SL. Late toxicity after intensity-modulated radiation therapy for localized prostate cancer: an exploration of dose-volume histogram parameters to limit genitourinary and gastrointestinal toxicity. Int J Radiat Oncol Biol Phys. 2012;82(1):235–41.

    Article  PubMed  Google Scholar 

  14. Kupelian PA, Willoughby TR, Reddy CA, Klein EA, Mahadevan A. Impact of image guidance on outcomes after external beam radiotherapy for localized prostate cancer. Int J Radiat Oncol Biol Phys. 2008;70(4):1146–50.

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We want to thank Philip Bastable for his review and corrections of the wording in this manuscript.

Funding

None.

Availability of data and materials

The data will not be shared as other original publications are under consideration.

Authors’ contributions

CM, PW and GC designed the study. CM, PW, MG, CD, SN, FM and EM contributed to data acquisition and analysis. CM and GC drafted the manuscript and PM, PW, EM and MG revised the manuscript critically. All authors have approved the final version to be published.

Competing interests

The authors declare that they have no competing interests.

Consent for publication

Not applicable.

Ethics approval and consent to participate

The institutional committee of the Centre Georges François Leclerc on human research approved the study. All of the patients analyzed in the present study had provided written consent in our establishment for the use of their clinical data to conduct retrospective studies.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Céline Mirjolet.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Mirjolet, C., Walker, P.M., Gauthier, M. et al. Absolute volume of the rectum and AUC from rectal DVH between 25Gy and 50Gy predict acute gastrointestinal toxicity with IG-IMRT in prostate cancer. Radiat Oncol 11, 145 (2016). https://doi.org/10.1186/s13014-016-0721-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13014-016-0721-8

Keywords