Skip to main content

Main menu

  • Home
  • Current Issue
  • Archive
  • Info for
    • Authors
    • Advertisers
    • Editorial Board
  • Other Publications
    • Anticancer Research
    • Cancer Genomics & Proteomics
    • Cancer Diagnosis & Prognosis
  • More
    • IIAR
    • Conferences
  • About Us
    • General Policy
    • Contact
  • Other Publications
    • In Vivo
    • Anticancer Research
    • Cancer Genomics & Proteomics

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
In Vivo
  • Other Publications
    • In Vivo
    • Anticancer Research
    • Cancer Genomics & Proteomics
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
In Vivo

Advanced Search

  • Home
  • Current Issue
  • Archive
  • Info for
    • Authors
    • Advertisers
    • Editorial Board
  • Other Publications
    • Anticancer Research
    • Cancer Genomics & Proteomics
    • Cancer Diagnosis & Prognosis
  • More
    • IIAR
    • Conferences
  • About Us
    • General Policy
    • Contact
  • Visit iiar on Facebook
  • Follow us on Linkedin
Research ArticleClinical Studies

Fluoroscopic Intraoperative Images Produce Higher Image Quality and Decrease Total Radiation Exposure Compared to Radiographic X-ray Images in Patients After Primary Total Knee Arthroplasty

TILMAN GRAULICH, JULIUS GERHARDY, MARCUS ÖRGEL, TAREK OMAR-PACHA, MOHAMED OMAR, CHRISTIAN KRETTEK and DANIEL GUENTHER
In Vivo September 2020, 34 (5) 2521-2526; DOI: https://doi.org/10.21873/invivo.12069
TILMAN GRAULICH
1Trauma Department, Hannover Medical School, Hannover, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: graulich.tilman@mh-hannover.de
JULIUS GERHARDY
1Trauma Department, Hannover Medical School, Hannover, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
MARCUS ÖRGEL
1Trauma Department, Hannover Medical School, Hannover, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
TAREK OMAR-PACHA
1Trauma Department, Hannover Medical School, Hannover, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
MOHAMED OMAR
1Trauma Department, Hannover Medical School, Hannover, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
CHRISTIAN KRETTEK
1Trauma Department, Hannover Medical School, Hannover, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
DANIEL GUENTHER
2Department of Orthopaedic Surgery, Trauma Surgery, and Sports Medicine, Cologne Merheim Medical Centre, Witten/Herdecke University, Cologne, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Background/Aim: Proper radiographic documentation of implant alignment is needed to analyse malrotation and malpositioning. We examined whether intraoperative fluoroscopic images can achieve more accurate image quality than postoperative radiographic X-ray images. Patients and Methods: We prospectively analysed 30 consecutive patients after total knee arthroplasty (TKA). We compared intraoperative fluoroscopic images with postoperative radiographic X-ray images. Radiation exposure was documented. Results: Fluoroscopic anterior-posterior images could achieve accurate image quality in 77% compared to 60% in radiographic images (p=0.016) and 54% compared to 34% on lateral view, respectively (p=0.008). Very good intra-observer correlation for fluoroscopic images could be achieved for femoral α angle with 0.84. Radiation exposure was 0.087+/-0.128 mGy. Conclusion: We observed significantly better image quality in fluoroscopic images than in radiographic X-ray images. The observed radiation exposure is lower than those expected for radiographic X-ray images. We conclude that fluoroscopic images can produce higher image quality and decreased radiation exposure.

  • Total knee arthroplasty
  • fluoroscopy
  • radiographic images
  • X-ray
  • accuracy
  • precision

Exact component fixation and alignment of total knee arthroplasty (TKA) is imperative to reduce postoperative pain and obtain patient satisfaction and good clinical function (1-4). Therefore proper radiographic documentation of coronal and sagittal implant alignment is needed to analyse malrotation and malpositioning (5, 6). Due to a lack of consistency in roentgenographic reporting of findings, rating systems have been described (2, 5, 7). The original Knee Society Clinical Rating System had been described in 1989 by Ewald et al. and has been adapted by Meneghini et al. They intended to modernized and updated the radiographic evaluation system as a rising diversity and complexity in implant design came up. Therfore they aimed to accumulate radiographic data in a standardized manner (5, 7, 8). In addition, a well aligned postoperative image is inevitable for compareability to detect implant loosening over time.

However, accurate and precise radiographic images are difficult to obtain as they depend on several parameters. Using either standing or portable radiographs for the measurement of the knee joint centre gives significant different values due to changes in the rotation of the knee in the presence of knee flexion (9). Limb rotation and knee flexion of 10°, either alone or in combination, has a significant effect on measured values of the anatomic alignment (10-13). Further patients' specific parameters like pain and casts can make proper radiograph acquisition challenging.

Looking for improvement of measured parameter reliability and reproducibility, the use of 3D-CT has shown better reliability than 2D-CT. However, radiation exposure is much higher compared to radiographic X-ray images (1, 14).

The use of intraoperative fluoroscopy of the anaesthetized patient reduces the patient's incompliances due to pain and could be a tool to improve image acquisition. It has been shown that fluoroscopically assisted radiographs increased the sensitivity of detecting tibial component loosening over standard radiographic X-rays after TKA during regular follow up (15). The amount of additional radiation dose is variable between the patients as the number of images and the exposure time varies. An extra amount corresponding to 8-12 images is needed to produce accurate fluoroscopic images. This summarizes about 5-10 seconds of fluoroscopic exposure time. An fluoroscopic exposure rate of 1 mGy/minute is described in the literature with a consecutive exposure of 0.05-0.15 mGy (15). In comparison, a standard knee radiographic image has an exposure of 0.05-0.1 mGy as well. Taking the specific tissue properties into consideration, the effective dose is lower than 0.005 mSv per standard knee radiograph (15).

The purpose of this study was to analyse if i) intraoperative fluoroscopy can produce a more accurate image quality than postoperative X-ray and ii) differences in the TKA-analysing angles, as described by the Knee Society Clinical Rating System, can be observed.

The hypothesis of the study was that fluoroscopic images can produce more accurate images than postoperative radiographic X-ray and that measured angles are different between fluoroscopic images and postoperative X-rays.

Patients and Methods

We prospectively analysed 28 consecutive knees in 30 patients who underwent TKA in our level one trauma centre. Two patients had to be excluded due to incomplete image acquisition with missing radiographic X-ray patellar images due to pain during flexion. The sample size was restricted due to the prospective design of the study, as well as radiation exposure of the patients. The knee implant used in all cases was the iTotal-Conformis knee prosthesis eather cruciate retaining (CR) or posterior stabalized (PS) (ConforMIS Inc., Billerica, MA, USA). The study was approved by our local ethics committee (Nr 7729_BO_S_2018). Informed consent was obtained from the patients.

Fluoroscopy- and radiographic X-ray imaging. Intraoperative fluoroscopic images were taken by a board certified orthopaedic surgeon. For the anterior-posterior (ap) view, the patient was in supine position, and the patellar was determined by palpation. The X-ray beam was set perpendicular to the joint line and perpendicular to the midshaft of the femur and tibia (7). For the lateral view, the X-ray beam was directed laterally, again perpendicular to the joint line. The patella was evaluated using 30° axial-/skyline-/Merchant-view (7, 8). The images were repeated until the surgeon believed to have accurate image quality. Imaging was considered accurate if i) central positioning of the patella in the AP view and 1/3 of the fibular head was behind the tibia, ii) complete overlapping of the medial and lateral condyle in the lateral view and iii) the patella was observed in the trochlear groove (8, 16).

Postoperatively, radiographic X-ray images were taken by trained radiological medical techniqual assistants (MTA). For the ap view, the X-ray beam was perpendicular to the joint line while for the lateral view, the beam was directed laterally and perpendicular to the joint line and for the patella we used 30° axial views. Images were not repeated if they were not strictly correct. Both, fluoroscopic images and radiographic X-ray images were evaluated by two trained orthopaedic surgeons as either accurate or non-accurate (yes/no) twice in an interval of four weeks.

Measurements using the modern knee society radiographic evaluation system.

Anteriorposterior view/Coronal alignment: The α angle for alignment of the femoral component was measured between the femoral shaft axis and the articular surface of the femoral component. The β angle for alignment of the tibial component, defined as the angle between the tibial shaft axis, which was determined by the center of four carticalices-marking dots, and the articular surface of the tibial component, was measured (1, 5, 7) (Figure 1 a,d).

Lateral view/Sagittal alignment: The γ angle for alignment of the femoral component was measured between the most distal femoral fixation surface and the femoral shaft axis. The δ angle or tibial slope angle was measured between the tibial shaft axis and the articular surface line of the tibial component (1, 5, 7) (Figure 1 b,e).

Merchant view/Patellofemoral alignment: The γ angle or patellar tilt angle was determined by the anterior surface of the femoral component and the axis of the patellar (1, 5, 7) (Figure 1 c,f).

Statistical analysis. An a priori sample size calculation was performed on the given data by Chalmers et al. (15). A required sample size of 26 knees was calculated. Data was summarized using Microsoft Excel® (Microsoft Corporation, Redmond, WA, USA) software and statistical analysis was performed with IBM SPSS Statistics® Version 25 (SPSS Inc., Chicago, IL, USA). Angles on flouroscopic images and radiographic X-ray images were measured in random order. For intra-observer reliability, Pearson correlation testing was performed for scale-based variables and Spearman correlation testing for nominal based variables. To assess inter-observer reliability, the intraclass correlation coefficients (ICCs) between the measurements were compared. Perfect reliability is indicated by an ICC value of 1, very good 0.81 to 1, good 0.61 to 0.80, moderate 0.41 to 0.60 and poor reliability by ICC <0.40 (15). To evaluate the precise image quality, means between all measurements were compared. Data were tested for normal distribution with the Kolmogorov Smirnoff Test. If data were normally distributed for comparative statistics, the parametric t-test was used. If data were not normally distributed, the non-parametric Mann-Whitney U-test was used. To determine inter-observer reliability, the Pearson correlation r of the two measurements was calculated. Data was described by mean±standard deviation defining significance level at α=0.05.

Results

We included 28 consecutive knees in 30 patients. Out of these we included 20 men and 8 women with a mean age of 68+/-13 (range=25-87) years. Fluoroscopic images could achieve excellent image quality on AP images in 77% compared to 60% in radiographic X-ray images (p=0.016). Concerning lateral images, fluoroscopic images showed 54% accurate image quality compared to 34% in radiographic X-ray images (p=0.008). On patella images, fluoroscopic images showed no difference in image quality compared to radiographic images (40% vs. 50%; p=0.217).

Figure 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 1.

Flouroscopic image and radiographic X-ray image analysis and angle acquisition: a-c: flouroscopic images, d-f: radiographic X-ray images. a,d: Anteriorposterior view/Coronal alignment: BLUE. The α angle for alignment of the femoral component was measured between the femoral shaft axis and the articular surface of the femoral component. RED: The β angle for alignment of the tibial component between the tibial shaft axis and the articular surface of the tibial component was measured. (1,5,7) b,e: Lateral view/Sagittal alignment. BLUE: The γ angle for alignment of the femoral component was measured between the most distal femoral fixation surface and the femoral shaft axis. RED: The δ angle or tibial slope angle was measured between the tibial shaft axis and the articular surface line of the tibial component. c,f: Merchant view/Patellofemoral alignment.: BLUE: The γ angle or patellar tilt angle was determined by the anterior surface of the femoral component and the axis of the patellar.

Intra-observer correlation was heterogeneous (Table I). Very good correlation could be achieved for the femoral α angle with 0.84 and good correlation for the patella γ angle and femoral γ angle with 0.773 and 0.657, respectively, on fluoroscopic images. For correlation between fluoroscopic and radiographic X-ray images, good correlation could be achieved for femoral α angle with 0.692. Further correlation testing showed only poor results.

Inter-observer correlation for fluoroscopic vs. fluoroscopic images was very good for femoral α angle with 0.844 and good for patellar γ angle with 0.726. Fluoroscopic- vs. radiographic X-ray images showed only poor correlation between both observers (Table II).

Comparing fluoroscopic and radiological data, the femoral flexion angle α was 94°+/-4° on fluoroscopic images vs. 95°+/-3° on postoperative radiographic X-ray images (p=0.283). The tibial angle β was 88°+/-2° on fluoroscopic images vs. 88°+/-2° on postoperative radiographic X-ray images (p=0.681), the femoral flexion γ was 13°+/-3° on fluoroscopic images vs. 10°+/-2° on postoperative radiographic X-ray images (p=0.004), the tibial angle δ was 89°+/-2° on fluoroscopic images vs. 87°+/-3° on postoperative radiographic X-ray images (p=0.145) and on patellar skyline-view the patellar tilt angle γ was 4.5+/-8 on fluoroscopic images and 1+/-8 on postoperative radiographic X-ray images (p=0.015).

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table I.

Intra-observer reliability for measured fluoroscopic and radiographic angles. Intraclass correlation coefficients (ICC). AP, Antero-posterior.

Radiation. Radiation exposure was 0.087+/-0.128 mGy. Exposure time was 20+/-21 s. Exposure rate was not significantly different for good/not-good AP-images, lateral-images and patella-images (p>0.05).

Discussion

In our study we compared intraoperative fluoroscopic- and postoperative radiographic X-ray images of the knee after TKA for their accuracy and precision, determined intra- and inter-observer reliability, and measured radiation exposure. Three major findings could be observed. First, we could find significant more accurate image quality in fluoroscopic images than in radiographic images. Second, our data show very good intra- and inter-observer correlation for femoral α angle and patellar γ angle on fluoroscopic and radiographic images. Further good intra- and inter-observer correlations could be observed. Third, the observed radiation exposure is equal to those described in the literature and lower than those expected for radiographic X-ray images. We therefore conclude that fluoroscopic intraoperative images can produce a better image quality and reduce total radiation exposure in patients after TKA. That means that the hypothesis of the study, that a better image accuracy can be achieved by fluoroscopic images was confirmed by our data. Differences in precision of the measured angles were seen in tibial angles, but not in femoral and patellar angles, which confirms our second hypothesis only partially.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table II.

Inter-observer reliability for measured fluoroscopic and radiographic angles. Intraclass correlation coefficients (ICC).

Fluoroscopic images have been shown to improve detection of radiolucent lines (17, 18). The general benefit of fluoroscopic images compared to radiographic X-ray images to detect pathologies like loose components in TKA is an improvement of 10% precision on the AP and lateral views (15). Our data show fluoroscopic images can produce nearly 20% more accurate images in both the AP and lateral view than conventional postoperative radiographic images. Additionally, we have to consider that two patients were not able to participate in patellar imaging due to pain. This might even increase the number of accurate images. We believe that further improvements of fluoroscopic image accuracy were sacrificed in order to reduce the exposure to intraoperative radiation. We therefore think that fluoroscopic images might help to improve the analysis of malpositioning and malrotation and help to detect implant loosening (5, 6). This has to be tested in further analyses.

Correlation testing for fluoroscopic images vs. fluoroscopic images, revealed very good to good intra- and inter-observer correlation. As fluoroscopic- and radiographic X-ray images differed, poor intra- and inter-observer correlation could be observed. Interestingly tibial angles showed worse correlation testing than femoral angles. For fluoroscopic images on AP view, less tibial than femoral bone for reliable tibial shaft axis determination during the measurement of the β angle might have been the reason for poor intra- and inter-observer correlation. A recent study has shown that postoperative standing long leg radiographic X-ray images (30×60 cm) after primary TKA are an equal accurate procedure to determine both anatomical and mechanical axis compared to standing long lag radiographic X-ray images (19). As the distance of the knee to the image intensifier correlates with the magnification and the size of the projected field of view, differences in the amount of the projected tibial shaft might have been present between the images. A less precise determination of the measured angles and thus a smaller intra- and inter-rater correlation might have been the result. Furthermore, the tibial joint line to determine the δ angle/tibial slope seems to be more affected by rotation than femoral angles. Limb rotation and knee flexion of 10°, either alone or in combination can significantly affect measured values of the anatomic alignment; this can explain the poor correlation of measured angles between fluoroscopic images and radiographic X-ray images (10-13).

Furthermore the measured radiation exposure with 0.087+/-0.128 mGy is comparable to data from the literature (15). Whereas one standard knee radiographic image has an exposure of 0.05-0.1 mGy, our total image acquisition radiation exposure is approximately 1/3 of total postoperative radiation and we therefore believe that fluoroscopic images should be used to gain better images and improve patients' safety by means of reduced radiation exposure. We believe that, as fluoroscopic images can be more precise than radiographic X-ray images, postoperative radiographic X-ray images are not necessary anymore.

Of note, the measured angles and images were obtained from patients undergoing TKA with prothesis from one manufacturer (Confomis ITotal eather CR or PS). Therefore, the external validity to other implants is reduced, however, internal validity, comparing data undergoing the same procedure, is high. The small sample size is one limitation. The sample size was restricted due to the prospective design of the study including radiation exposure of the patients. The number of patients is comparable to the literature and significant differences could be measured. Patient number is furthermore slightly above the required sample size as determined by a priori power analysis. Fluoroscopic images and radiographic images have not been obtained by the same surgeon. However, as radiographic images have been obtained by trained MTA performing radiographic images on a daily routine base, the results are even more impressive.

Conclusion

We could find significantly better image quality in fluoroscopic images than in radiographic X-ray images. Our data show very good intra- and inter-observer correlation for the femoral α angle and patellar γ angle on fluoroscopic and radiographic images. The observed radiation exposure is equal to those described in the literature and lower than those expected for radiographic X-ray images. We therefore conclude that fluoroscopic images can produce higher image quality and decrease the total radiation exposure compared to radiographic X-ray images in patients after TKA.

Footnotes

  • Authors' Contributions

    Data acquisition: TG, JG. Drafting and revising the manuscript: TG, JG, TOP, MÖ, MO, DG. Analysis and interpretation of data: TG, CK, DG. Study conception and design: TG, CK, DG.

  • This article is freely accessible online.

  • Conflicts of Interest

    The Authors declare no conflicts of interest.

  • Received May 19, 2020.
  • Revision received June 6, 2020.
  • Accepted June 9, 2020.
  • Copyright© 2020, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved

References

  1. ↵
    1. Hirschmann MT,
    2. Konala P,
    3. Amsler F,
    4. Iranpour F,
    5. Friederich NF,
    6. Cobb JP
    : The position and orientation of total knee replacement components. J Bone Joint Surg Br 93(5): 629-633, 2011. PMID: 21511928. DOI: 10.1302/0301-620X.93B5.25893
    OpenUrlCrossRefPubMed
  2. ↵
    1. Elmallah RK,
    2. Scuderi GR,
    3. Jauregui JJ,
    4. Meneghini RM,
    5. Dennis DA,
    6. Backstein DB,
    7. Bourne RB,
    8. Mont MA,
    9. Knee Society Roentgenographic Workgroup
    : Radiographic evaluations of revision total knee arthroplasty: A plea for uniform assessments. J Arthroplasty 30(11): 1981-1984, 2015. PMID: 26364904. DOI: 10.1016/j.arth.2015.08.013
    OpenUrl
    1. Brugioni DJ,
    2. Andriacchi TP,
    3. Galante JO
    : A functional and radiographic analysis of the total condylar knee arthroplasty. J Arthroplasty 5: 173-180, 1990. PMID: 2358816. DOI: 10.1016/s0883-5403(06)80237-8
    OpenUrlPubMed
  3. ↵
    1. Longstaff LM,
    2. Sloan K,
    3. Stamp N,
    4. Scaddan M,
    5. Beaver R
    : Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. J Arthroplasty 24(4): 570-578, 2009. PMID: 18534396. DOI: 10.1016/j.arth.2008.03.002
    OpenUrlCrossRefPubMed
  4. ↵
    1. Meneghini RM,
    2. Mont MA,
    3. Backstein DB,
    4. Bourne RB,
    5. Dennis DA,
    6. Scuderi GR
    : Development of a modern knee society radiographic evaluation system and methodology for total knee arthroplasty. J Arthroplasty 30: 2311-2314, 2015. PMID: 26122112. DOI: 10.1016/j.arth.2015.05.049
    OpenUrlCrossRefPubMed
  5. ↵
    1. Yaffe MA,
    2. Koo SS,
    3. Stulberg SD
    : Radiographic and navigation measurements of TKA limb alignment do not correlate. Clin Orthop Relat Res 466: 2736-2744, 2008. PMID: 18752032. DOI: 10.1007/s11999-008-0427-9
    OpenUrlCrossRefPubMed
  6. ↵
    1. Ewald FC
    : The knee society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248: 9-12, 1989. PMID: 2805502.
    OpenUrlPubMed
  7. ↵
    1. Bach CM,
    2. Nogler M,
    3. Wimmer C,
    4. Ogon M,
    5. Steingruber IE,
    6. Peer S
    : Radiographic assessment in total knee arthroplasty. Clin Orthop Relat Res 385: 144-150, 2001. PMID: 11302305. DOI: 10.1097/00003086-200104000-00022
    OpenUrlCrossRefPubMed
  8. ↵
    1. Younger ASE,
    2. Beachamp CP,
    3. Duncan CP,
    4. McGraw RW
    : Position of the knee joint after total joint arthroplasty. J Arthroplasty 10: 53-61, 1995. PMID: 7730831. DOI: 10.1016/s0883-5403(05)80101-9
    OpenUrlPubMed
  9. ↵
    1. Lonner JH,
    2. Laird MT,
    3. Stuchin SA
    : Effect of limb rotation on radiographic alignment in total knee arthroplasties. Clin Orthop Relat Res 331: 102-106, 1996. PMID: 8895625. DOI: 10.1097/00003086-199610000-00014
    OpenUrlCrossRefPubMed
    1. Swanson KE,
    2. Stocks GW,
    3. Warren PD,
    4. Hazel MR,
    5. Janssen HF
    : Does axial limb rotation affect the alignment measurements in deformed limbs? Clin Orthop Relat Res 371: 246-252, 2000. PMID: 10693572. DOI: 10.1097/00003086-200002000-00029
    OpenUrlCrossRefPubMed
    1. Lemaire P,
    2. Pioletti DP,
    3. Meyer FM,
    4. Meuli R,
    5. Dörfl J,
    6. Leyvraz PF
    : Tibial component positioning in total knee arthroplasty: Bone coverage and extensor apparatus alignment. Knee Surgery, Sport Traumatol Arthrosc 5: 251-257, 1997. PMID: 9430576. DOI: 10.1007/s001670050059
    OpenUrl
  10. ↵
    1. Hunt MA,
    2. Fowler PJ,
    3. Birmingham TB,
    4. Jenkyn TR,
    5. Giffin JR
    : Foot rotational effects on radiographic measures of lower limb alignment. Can J Surg 49: 401-406, 2006. PMID: 17234068.
    OpenUrlPubMed
  11. ↵
    1. Suter T,
    2. Zanetti M,
    3. Schmid M,
    4. Romero J
    : Reproducibility of measurement of femoral component rotation after total knee arthroplasty using computer tomography. J Arthroplasty 21: 744-748, 2006. PMID: 16877163. DOI: 10.1016/j.arth.2005.09.012
    OpenUrlCrossRefPubMed
  12. ↵
    1. Chalmers BP,
    2. Sculco PK,
    3. Fehring KA,
    4. Taunton MJ,
    5. Trousdale RT
    : Fluoroscopically assisted radiographs improve sensitivity of detecting loose tibial implants in revision total knee arthroplasty. J Arthroplasty 32: 570-574, 2017. PMID: 27665244. DOI: 10.1016/j.arth.2016.08.005
    OpenUrl
  13. ↵
    1. Kniesel B,
    2. Konstantinidis L,
    3. Hirschmüller A,
    4. Südkamp N,
    5. Helwig P
    : Digital templating in total knee and hip replacement: An analysis of planning accuracy. Int Orthop 38: 733-739, 2014. PMID: 24162155. DOI: 10.1007/s00264-013-2157-1
    OpenUrl
  14. ↵
    1. Fehring TK,
    2. McAvoy G
    : Fluoroscopic evaluation of the painful total knee arthroplasty. Clin Orthop Relat Res 331: 226-233, 1996. PMID: 8895643. DOI: 10.1097/00003086-199610000-00032
    OpenUrlCrossRefPubMed
  15. ↵
    1. Vyskocil P,
    2. Gerber C,
    3. Bamert P
    : Radiolucent lines and component stability in knee arthroplasty. Standard versus fluoroscopically-assisted radiographs. J Bone Joint Surg Br 81: 24-26, 1999. PMID: 10067995. DOI: 10.1302/0301-620x.81b1.9213
    OpenUrlCrossRefPubMed
  16. ↵
    1. Perka N,
    2. Kopf S,
    3. Hommel H
    : A whole leg radiograph is not necessary for postoperative determination of the mechanical leg axis after total knee arthroplasty. Arch Orthop Trauma Surg, 2019. PMID: 31414170. DOI: 10.1007/s00402-019-03256-x
PreviousNext
Back to top

In this issue

In Vivo: 34 (5)
In Vivo
Vol. 34, Issue 5
September-October 2020
  • Table of Contents
  • Table of Contents (PDF)
  • Index by author
  • Back Matter (PDF)
  • Ed Board (PDF)
  • Front Matter (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on In Vivo.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Fluoroscopic Intraoperative Images Produce Higher Image Quality and Decrease Total Radiation Exposure Compared to Radiographic X-ray Images in Patients After Primary Total Knee Arthroplasty
(Your Name) has sent you a message from In Vivo
(Your Name) thought you would like to see the In Vivo web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
8 + 5 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
Fluoroscopic Intraoperative Images Produce Higher Image Quality and Decrease Total Radiation Exposure Compared to Radiographic X-ray Images in Patients After Primary Total Knee Arthroplasty
TILMAN GRAULICH, JULIUS GERHARDY, MARCUS ÖRGEL, TAREK OMAR-PACHA, MOHAMED OMAR, CHRISTIAN KRETTEK, DANIEL GUENTHER
In Vivo Sep 2020, 34 (5) 2521-2526; DOI: 10.21873/invivo.12069

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Reprints and Permissions
Share
Fluoroscopic Intraoperative Images Produce Higher Image Quality and Decrease Total Radiation Exposure Compared to Radiographic X-ray Images in Patients After Primary Total Knee Arthroplasty
TILMAN GRAULICH, JULIUS GERHARDY, MARCUS ÖRGEL, TAREK OMAR-PACHA, MOHAMED OMAR, CHRISTIAN KRETTEK, DANIEL GUENTHER
In Vivo Sep 2020, 34 (5) 2521-2526; DOI: 10.21873/invivo.12069
del.icio.us logo Digg logo Reddit logo Twitter logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Patients and Methods
    • Results
    • Discussion
    • Conclusion
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Treatment of Renal Anemia in Patients With Hemodialysis Using Hypoxia-inducible Factor (HIF) Stabilizer, Roxadustat: A Short-term Clinical Study
  • Pediatric Patients With Sickle Cell Disease at a Public Hospital: Nutrition, Compliance and Early Experience With L-Glutamine Therapy
  • Five-year Follow-up of Patients With Head and Neck Cancer Treated With Nivolumab and Long-term Responders for Over Two Years
Show more Clinical Studies

Similar Articles

Keywords

  • Total knee arthroplasty
  • fluoroscopy
  • radiographic images
  • X-ray
  • accuracy
  • precision
In Vivo