Skip to main content

Main menu

  • Home
  • Current Issue
  • Archive
  • Info for
    • Authors
    • Editorial Policies
    • Advertisers
    • Editorial Board
    • Special Issues 2025
  • Journal Metrics
  • Other Publications
    • Anticancer Research
    • Cancer Genomics & Proteomics
    • Cancer Diagnosis & Prognosis
  • More
    • IIAR
    • Conferences
  • About Us
    • General Policy
    • Contact
  • Other Publications
    • In Vivo
    • Anticancer Research
    • Cancer Genomics & Proteomics

User menu

  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
In Vivo
  • Other Publications
    • In Vivo
    • Anticancer Research
    • Cancer Genomics & Proteomics
  • Register
  • Subscribe
  • My alerts
  • Log in
  • My Cart
In Vivo

Advanced Search

  • Home
  • Current Issue
  • Archive
  • Info for
    • Authors
    • Editorial Policies
    • Advertisers
    • Editorial Board
    • Special Issues 2025
  • Journal Metrics
  • Other Publications
    • Anticancer Research
    • Cancer Genomics & Proteomics
    • Cancer Diagnosis & Prognosis
  • More
    • IIAR
    • Conferences
  • About Us
    • General Policy
    • Contact
  • Visit iiar on Facebook
  • Follow us on Linkedin
Research ArticleClinical Studies

The Influence of Cardiac Pacemaker Programming Modes on Exercise Capacity

BOGDAN CALOIAN, ADELA VIVIANA SITAR-TAUT, GABRIEL NICOLAE GUSETU, DANA POP and DUMITRU TUDOR ZDRENGHEA
In Vivo March 2018, 32 (2) 419-424;
BOGDAN CALOIAN
1Cardiology-Rehabilitation Department, Clinical Rehabilitation Hospital, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
ADELA VIVIANA SITAR-TAUT
2Internal Medicine Department, Medical Clinic IV, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
GABRIEL NICOLAE GUSETU
1Cardiology-Rehabilitation Department, Clinical Rehabilitation Hospital, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
DANA POP
1Cardiology-Rehabilitation Department, Clinical Rehabilitation Hospital, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: pop67dana@gmail.com
DUMITRU TUDOR ZDRENGHEA
1Cardiology-Rehabilitation Department, Clinical Rehabilitation Hospital, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Background/Aim: The cardiac pacing mode influences the atrioventricular synchronicity and the response of the heart rate to physical exercise. The aim of this study was to compare the influence of the most common pacemaker programming modes on exercise capacity. Patients and Methods: Fifty-two pacemaker-wearing patients were clinically evaluated and submitted to an exercise stress test. Results: Symptoms of heart failure were more frequently met in the single-chamber pacemaker group compared to the dual-chamber group. The parameters recorded during the exercise stress test were significantly better with the rate responsive function (RRF) activated. The effort time was higher by an average of 2.1 minutes and the exercise capacity was higher by 0.92 metabolic equivalents. Conclusion: Dual-chamber pacing is superior to single-chamber (ventricular) pacing and the activation of the RRF in single-chamber pacemakers has similar impact on exercise capacity as the preservation of atrioventricular synchronicity by dual-chamber pacemakers.

  • Cardiac pacemaker
  • pacemaker programming modes
  • single-chamber pacing
  • dual-chamber pacing
  • rate responsive function
  • exercise capacity

A pacemaker not only has the role of preventing the heart rate from dropping under a certain limit, but can also have an important influence on the exercise capacity (1), as the pacing mode influences atrioventricular synchronicity (single-chamber vs. dual-chamber pacemakers) (2, 3) and the response of the heart rate to physical exercise (rate responsive function, mode switch function) (4, 5).

Most patients who have a pacemaker implanted for sick sinus syndrome or for atrioventricular blocks need to be enrolled in cardiac rehabilitation programs in order to improve their exercise capacity and quality of life. One of the most important components of cardiac rehabilitation is physical exercise, a programme that needs to be individualized for each patient by taking into account various factors such as age, gender, risk factors, comorbidities, and fitness level (6).

The first step in prescribing a physical training plan is the evaluation of the maximum exercise capacity of the patient through a standardized exercise stress test, noting the symptoms that forced the patient to stop the test, the maximum workload, the variations of the patient's blood pressure, heart rate, oxygen saturation, significant arrhythmias or ischemic changes recorded on the electrocardiographic (ECG) monitoring (7-9).

Besides the parameters mentioned above, the pacemaker-wearing patient needs a more complex assessment during exercise because some particular events might occur: the heart rate might not adapt to exercise in patients with chronotropic incompetence, resulting in early left ventricular failure; atrioventricular conduction disturbances could worsen, causing symptoms such as dyspnoea, dizziness or even syncope; tachyarrhythmia or ischemic changes can be difficult to diagnose on an ECG recording during paced atrial or ventricular beats (10, 11).

In the present study, we focused on the exercise capacity of patients with cardiac pacemakers and on the benefits or the disadvantages brought by choosing a particular programming mode. Most of the studies that evaluated the exercise capacity of pacemaker-wearing patients enrolled a limited number of individuals and returned discordant results.

The purpose of our study was to compare the influence of the most common pacemaker programming modes on the exercise capacity of the patients.

Materials and Methods

We conducted the study at the Cardiology Department of the Clinical Rehabilitation Hospital in Cluj-Napoca, Romania, including patients with a pacemaker implanted for more than 6 months and for whom we performed a cycloergometer exercise stress test following the adjusted Bruce protocol (12).

The anamnesis, complete physical examination, electrocardiography and echocardiography were performed before the exercise stress testing, during the same hospital admission. Symptoms and signs of heart failure were evaluated according to the 2016 European Society of Cardiology Guidelines for the diagnosis and treatment of acute and chronic heart failure (13).

Echocardiographic examinations were performed using either Philips Affiniti 70 Ultrasound Machine (Koninklijke Philips N.V., Amsterdam, Holland) or Esaote MyLab50 Ultrasound Machine (Esaote SpA, Genoa, Italy). The left atrial and left ventricular end-diastolic diameters were measured from parasternal long axis view and the ejection fraction was determined with Simpson's biplane formula (14).

Patients with comorbidities that could significantly impair exercise capacity (respiratory, neurological, musculoskeletal, vascular or significant structural heart diseases) were excluded from the study. Treatment with beta-blockers was stopped 24 hours before the test and resumed immediately after.

Pacemaker type and programming. The patients enrolled in the present study were wearing single-chamber pacemakers: Sensia SESR01 Implantable Pulse Generator (Medtronic, Minneapolis, MN, USA) or Sustain XL SR (St. Jude Medical, Saint Paul, MN, USA), or dual-chamber pacemakers: SEDR01 Sensia DR (Medtronic) or Sustain XL DR (St. Jude Medical). The implanted devices mentioned above were interrogated to determine the programming parameters using Medtronic Pacemaker and ICD Programmer model 2090 (Medtronic) and St. Jude Medical Merlin Patient Care System (St. Jude Medical). The pacemaker programming parameters were not modified prior to the test, all patients that were tested remained with the pacemaker settings selected by their personal cardiologist.

Statistical analysis. The data obtained were statistically analysed using IBM SPSS Statistics Software version 23 (International Business Machines Corporation, Armonk, North Castle, New York, NY, USA) and Microsoft Office 2013 Excel Data Analysis (Microsoft Corp., Redmond, WA, USA) module. The chi-square test was used for qualitative (categorical) variables, while mean, standard deviation and Student t-test were applied for quantitative variables. The normality of all variables distribution was studied with the Kolmogorov-Smirnov test. To calculate the correlation coefficient, for variables with normal distribution, the ANOVA test was applied and for variables without a normal distribution, non-parametrical Kruskal–Wallis test was used. Statistic significance was considered present when the p-value was below 0.05.

Ethics. The present clinical study was approved by the local Ethics Committee (approval number 115/6.01.2017) and was performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki and its later amendments. All patients included in the present study gave their informed consent.

Results

We included in our study 52 patients, of whom 31 were males (59.6%). Eleven patients were in atrial fibrillation (21.1%), all wearing a single-chamber (ventricular) pacemaker. The baseline characteristics of the patients included in our study are presented in Table I.

When we analysed the patients taking into account the pacemaker type, either dual-chamber or single-chamber pacemaker, we found that at admission, the symptoms of heart failure were more frequently met in the single-chamber pacemaker group (64.5%) compared to the dual-chamber pacemaker group (42.85%), reaching statistical significance (p=0.013). In the dual-chamber pacemaker group, the rate responsive function (RRF) of the pacemaker was non-significantly more frequently activated (57.1% vs. 38.7%, respectively, p=0.22).

Although the left ventricular ejection fraction was higher and the left atrial and left ventricular diameters were lower in the dual-chamber pacemaker group, the difference was not statistically significant.

When we analysed the impact of the activation of RRF on symptoms of heart failure, echocardiography parameters and exercise capacity, we observed the following: the symptoms of heart failure were more frequently met when RRF was deactivated (67.85% vs. 41.67%, p=0.008); the left ventricular ejection fraction was higher and left atrial and left ventricular diameters were lower in patients with the RRF activated, but the differences did not reach statistical significance. The parameters recorded during the exercise stress test were significantly better with RRF activated. The effort time was higher by an average of 2.1 minutes (p=0.013), the maximum workload was higher by an average of 21 W (p=0.029) and the exercise capacity estimated in metabolic equivalents (METs) was higher by an average of 0.92 (p=0.034) (Table II).

There were four types of patients submitted to an exercise stress test considering their pacemaker programming mode: single-chamber without RRF activated (19 patients), single-chamber with RRF activated (12 patients), dual-chamber without RRF activated (nine patients) and dual-chamber with RRF activated (12 patients).

Patients in the group with dual-chamber with RRF had the best exercise capacity during the exercise stress test (5.56±1.18 METs), while patients in the group with single-chamber without RRF had the worst exercise capacity (3.97±1.50 METs) and patients in groups with single-chamber with RRF and dual-chamber without RRF had intermediate values (5.07±1.56 and 5.28±1.65, respectively) (Figure 1).

Backward multiple regression that included age, gender, pacing mode, resting heart rate, end diastolic left ventricular diameter, and left atrial diameter as variables identified the pacing programming mode as an independent predictor for exercise capacity estimated in METs in men (r=0.51, p=0.014), but not in women (r=0.08, p=0.76) (Figure 2).

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table I.

Baseline characteristics of patients with dual-chamber (DDD) and single-chamber pacemakers (VVI). Dual chamber pacemakers have dual pacing (right atrium and right ventricle), dual sensing (right atrium and right ventricle), and dual response type (triggering and inhibition). Single-chamber pacemakers are able to perform ventricular pacing, ventricular sensing and respond by inhibition. Both pacemaker types can have rate responsive function activated or not.

View this table:
  • View inline
  • View popup
  • Download powerpoint
Table II.

Influence of rate responsive function activation on clinical, echocardiography and exercise testing parameters.

Discussion

The pacemaker programming mode has an important influence on a patient's exercise capacity. Our results show that even though the patients had similar left ventricular ejection fraction, and left atrial and left ventricular diameters, the patients in whom the RRF of the pacemaker was activated had superior functional capacity proven by their exercise test parameters.

The results of previous clinical studies conducted in this field are discordant. Provenier and Jordaens (1994) showed that activating the RRF significantly increased the walking distance during a 6-minute walking test in 16 patients wearing a single chamber pacemaker (15).

On the contrary, in a more recently published article (2010), Uebing et al. stated that the activation of the same pacemaker function did not improve functional capacity in nine patients evaluated based on exercise test results (16).

Better functional capacity was also observed in our study in patients with dual-chamber pacemakers in comparison to single-chamber (ventricular) pacemakers, an expected result taking into account the fact that dual-chamber pacemakers preserve the atrioventricular synchronicity which increases cardiac output by up to 25% (17, 18). Chabernaud et al. compared single-chamber and dual-chamber pacing modes in 10 patients, observing a superior exercise capacity with dual-chamber pacing mode (19).

In our study, the best exercise capacity was observed in patients with dual-chamber pacemaker with RRF activated, followed by those with dual-chamber without RRF activated and by single-chamber with RRF activated, the worst exercise capacity being noted in those with single-chamber pacemaker without RRF activated. Maity et al. concluded, after developing a clinical study with 10 patients, that the activation of RRF had a more considerable effect on the exercise capacity than upgrading from single- to dual-chamber pacing, although the upgrade also significantly improved the exercise test results (20).

Figure 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 1.

The influence of pacing programming modes on exercise capacity expressed in metabolic equivalents (METs). Patients wearing dual-chamber pacemakers with rate responsive function (RRF) activated (DDDR) had the best exercise capacity, while those with single-chamber pacemakers without RRF activated (VVI) had the worst exercise capacity. There was no significant difference between dual-chamber pacing, RRF not activated (DDD) and single-chamber pacing, RRF activated (VVIR).

Figure 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 2.

Gender differences in exercise capacity [mean metabolic equivalents (METs) and 95% confidence interval] for the studied pacing modes. Pacing programming mode represents an independent predictor for exercise capacity in men, but not in women. VVI: Single-chamber pacemaker without rate responsive function (RRF) activated, VVIR: single-chamber pacemaker with RRF activated, DDD: dual-chamber pacemaker without RRF activated, DDDR: dual-chamber pacemaker with RRF activated.

The discordance between the results of previous clinical studies can be mainly explained by the small number of patients enrolled, and the fact that most of the patients wearing a pacemaker were unable to perform an exercise stress test because of the comorbidities associated with older age.

One of the most interesting and important observations of our research, also confirmed by other studies (21-24), is that patients with dual-chamber without RRF and those with single-chamber with RRF had similar exercise capacity. This means that the activation of a simple function of the pacemaker has the same benefits as preserving the contribution of the atrial contraction to cardiac output. In other words, a patient with permanent atrial fibrillation and a single-chamber pacemaker will be able to gain the exercise capacity of a patient wearing a dual-chamber pacemaker with preserved atrial contractions if the RRF is activated. On the other hand, a patient in sinus rhythm who receives a single-chamber ventricular pacemaker loses the benefits brought by atrial contraction and their exercise capacity descends to that of a patient with permanent atrial fibrillation. This observation is even more important if we take into account that RRF is not activated by default in all cardiac pacemaker types.

The activation of RRF proved to be beneficial irrespective of the presence of chronotropic incompetence, which was not taken into account, a fact that we consider a limitation of our study.

In women, the programming mode did not reach statistical significance as a predictor for exercise capacity, most probably because of the small number of female patients included in the study.

Taking into account that patients with single-chamber without RRF had the worst exercise capacity, the use of this programming mode should be limited only to cases in which comorbidities severely impair their physical activity. Otherwise, patients in atrial fibrillation should receive a single-chamber pacemaker with RRF activated and patients in sinus rhythm a similarly activated dual-chamber device.

In conclusion, the pacemaker programming mode significantly influences the exercise capacity. Dual-chamber pacing is superior to single-chamber (ventricular) pacing and the activation of the RRF in single-chamber pacemakers has a similar impact on exercise capacity as does preservation of atrioventricular synchronicity in dual-chamber pacemakers. These observations should be considered by physicians when they program a pacemaker or prescribe physical rehabilitation.

Footnotes

  • This article is freely accessible online.

  • Received December 2, 2017.
  • Revision received January 11, 2018.
  • Accepted January 16, 2018.
  • Copyright © 2018 The Author(s). Published by the International Institute of Anticancer Research.

References

  1. ↵
    1. Oliveira RM,
    2. da Silva KR,
    3. Kawauchi TS,
    4. Alves LB,
    5. Crevelari ES,
    6. Filho MM,
    7. Costa R
    : Functional capacity of patients with pacemaker due to isolated congenital atrioventricular block. Arq Bras Cardiol 104(1): 67-77, 2015.
    OpenUrl
  2. ↵
    1. Nielsen JC,
    2. Kristensen L,
    3. Andersen HR,
    4. Mortensen PT,
    5. Pedersen OL,
    6. Pedersen AK
    : A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome. J Am Coll Cardiol 42: 614-623, 2003.
    OpenUrlFREE Full Text
  3. ↵
    1. Kinderman M,
    2. Hennen B,
    3. Jung J,
    4. Geisel J,
    5. Bohm M,
    6. Frohlig G
    : Biventricular versus conventional right ventricular stimulation for patients with standard pacing indication and left ventricular dysfunction: The Homburg Biventricular Pacing Evaluation (HOBIPACE). J Am Coll Cardiol 47: 1927-1937, 2006.
    OpenUrlFREE Full Text
  4. ↵
    1. Palmisano P,
    2. Aspromonte V,
    3. Ammendola E,
    4. Delléra G,
    5. Ziacchi M,
    6. Guerra F,
    7. Aquilani S,
    8. Maglia G,
    9. Del Giorno G,
    10. Giubertoni A,
    11. Boriani G,
    12. Capucci A,
    13. Pietro Rici R,
    14. Accogli M
    : Effect of fixed-rate vs. rate-responsive pacing on exercise capacity in patients with permanent, refractory atrial fibrillation and left ventricular dysfunction treated with atrioventricular junction ablation and biventricular pacing (RESPONSIBLE): a prospective, multicentre, randomized, single-blind study. EP Europace 19(3): 414-420, 2017.
    OpenUrl
  5. ↵
    1. Passman RS,
    2. Weinberg KM,
    3. Freher M,
    4. Denes P,
    5. Schaechter A,
    6. Goldberger JJ,
    7. Kadish AH
    : Accuracy of mode switch algorithms for detection of atrial tachyarrhythmias. J Cardiovasc Electrophysiol 15: 773-777, 2004.
    OpenUrlCrossRefPubMed
  6. ↵
    1. Greco EM,
    2. Guardini S,
    3. Citelli L
    : Cardiac rehabilitation in patients with rate responsive pacemakers. Pacing Clin Electrophysiol 21: 568-575, 1998.
    OpenUrlPubMed
  7. ↵
    1. Calvagna GM,
    2. Patane S
    : Cardiac rehabilitation in pacing patient complications: an increasing scenario requiring a collaborative vision of a multi-disciplinary treatment team. Int J Cardiol 178: 168-170, 2015.
    OpenUrl
    1. Gostoli S,
    2. Roncuzzi R,
    3. Urbinati S,
    4. Rafanelli C
    : Clinical and subclinical distress, quality of life, and psychological well-being after cardiac rehabilitation. Appl Psychol Health Well Being 9(3): 349-369, 2017.
    OpenUrl
  8. ↵
    1. Zdrenghea D,
    2. Ilea M,
    3. Pop D,
    4. Petrovai D,
    5. Bodisz G,
    6. Zdrenghea M
    : N-terminal pro B-type natriuretic peptide during exercise in patients with systolic and diastolic heart failure. Acta Endo 5(1): 19-25, 2009.
    OpenUrl
  9. ↵
    1. Zdrenghea D,
    2. Pop D,
    3. Gusetu G
    : The rehabilitation in cardiac resynchronisation therapy. In: Cardiac Rehabilitation Manual. Niebauer J. Springer International Publishing pp. 245-256, 2017.
  10. ↵
    1. Iliou MC,
    2. Blanchard JC,
    3. Lamar-Tanguy A,
    4. Cristofini P,
    5. Ledru F
    : Cardiac rehabilitation in patients with pacemakers and implantable cardioverter defibrillators. Monaldi Arch Chest Dis 86(1-2): 756, 2016.
    OpenUrl
  11. ↵
    1. Hill J,
    2. Timmis A
    : Exercise tolerance testing. BMJ 324(7345): 1084-1087, 2002.
    OpenUrlFREE Full Text
  12. ↵
    1. Ponikowski P,
    2. Voors AA,
    3. Anker SD,
    4. Bueno H,
    5. Cleland JC,
    6. Coats AJS,
    7. Falk V,
    8. González-Juanatey JR,
    9. Harjola VP,
    10. Jankowska EA,
    11. Jessup M,
    12. Linde C,
    13. Nihoyannopoulos P,
    14. Parissis JT,
    15. Pieske B,
    16. Riley JP,
    17. Rosano GMC,
    18. Ruilope LM,
    19. Ruschitzka F,
    20. Rutten FH,
    21. van der Meer P
    : 2016 ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure: The Task Force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC) Developed with the special contribution of the Heart Failure Association (HFA) of the ESC. Eur Heart J 37(27): 2129-2200, 2016.
    OpenUrlCrossRefPubMed
  13. ↵
    1. Schiller NB,
    2. Shah PN,
    3. Crawford M
    : Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. J Am Soc Echocardiogr 2: 258-267, 1989.
    OpenUrl
  14. ↵
    1. Provenier F,
    2. Jordaens L
    : Evaluation of six minute walking test in patients with single chamber rate responsive pacemakers. Br Heart J 72(2): 192-196, 1994.
    OpenUrlAbstract/FREE Full Text
  15. ↵
    1. Uebing A,
    2. Diller GP,
    3. Li W,
    4. Maskell M,
    5. Dimopoulos K,
    6. Gatzoulis MA
    : Optimised rate-responsive pacing does not improve either right ventricular haemodynamics or exercise capacity in adults with a systemic right ventricle. Cardiol Young 20(5): 485-494, 2010.
    OpenUrlCrossRefPubMed
  16. ↵
    1. Rodriguez Munoz DA,
    2. Moya Mur JL,
    3. Becker D,
    4. Fernandez Santos S,
    5. Lazaro Rivera C,
    6. Casas Rojo E,
    7. Navas Tejedor P,
    8. Delgado Montero A,
    9. Fernandez-Golfin C,
    10. Zamorano Gomez JL
    : Atrial systole contribution to cardiac output: more than just volume. Eur Heart J 34: 1122, 2013.
    OpenUrlCrossRefPubMed
  17. ↵
    1. Klautz RJ,
    2. Baan J,
    3. Teitel DF
    : Contribution of synchronized atrial systole to left ventricular contraction in the newborn pig heart. Pediatr Res 43(3): 331-337, 1998.
    OpenUrlPubMed
  18. ↵
    1. Chabernaud JM,
    2. Guéret P,
    3. Blanc P,
    4. Bavoux O,
    5. Bensaid J
    : Comparison of VVI and DDD cardiac stimulation during exercise test evaluated by respiratory gas exchange measurement. Study of patients with normal systolic function and complete atrioventricular block unchanged during exercise test. Arch Mal Coeur Vaiss 86(1): 69-74, 1993.
    OpenUrlPubMed
  19. ↵
    1. Maity AK,
    2. Ghosh SP,
    3. Dasbiswas A,
    4. Chatterjee SS,
    5. Chaudhury D,
    6. Das MK
    : Haemodynamic advantage with single-chamber rate responsive pacemakers over dual-chamber pacemakers during exercise in chronotropic incompetence. Indian Heart J: 44(4): 231-234, 1992.
    OpenUrlPubMed
  20. ↵
    1. Oldroyd KG,
    2. Rae AP,
    3. Carter R,
    4. Wingate C,
    5. Cobbe SM
    : Double blind crossover comparison of the effects of dual chamber pacing (DDD) and ventricular rate adaptive (VVIR) pacing on neuroendocrine variables, exercise performance, and symptoms in complete heart block. Br Heart J 65(4): 188-193, 1991.
    OpenUrlAbstract/FREE Full Text
    1. Linde-Edelstam C,
    2. Hjemdahl P,
    3. Pehrsson SK,
    4. Aström H,
    5. Nordlander R
    : Is DDD pacing superior to VVIR? A study on cardiac sympathetic nerve activity and myocardial oxygen consumption at rest and during exercise. Pacing Clin Electrophysiol 15(4 Pt 1): 425-434, 1992.
    OpenUrlPubMed
    1. Lau DH,
    2. Thiyagarajah A,
    3. Willems S,
    4. Rostock T,
    5. Linz D,
    6. Stiles MK,
    7. Kaye D,
    8. Kalman JM,
    9. Sanders P
    : Device therapy for rate control: pacing, resynchronisation and AV node ablation. Heart Lung Circ 26(9): 934-940, 2017.
    OpenUrl
  21. ↵
    1. Lau CP,
    2. Tai YT,
    3. Leung WH,
    4. Leung SK,
    5. Li JP,
    6. Wong CK,
    7. Lee IS,
    8. Yerich C,
    9. Erickson M
    : Rate adaptive cardiac pacing using right ventricular venous oxygen saturation: quantification of chronotropic behaviour during daily activities and maximal exercise. Pacing Clin Electrophysiol 17(12 Pt 1): 2236-2246, 1994.
    OpenUrlCrossRefPubMed
PreviousNext
Back to top

In this issue

In Vivo
Vol. 32, Issue 2
March-April 2018
  • Table of Contents
  • Table of Contents (PDF)
  • Index by author
  • Back Matter (PDF)
  • Ed Board (PDF)
  • Front Matter (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on In Vivo.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The Influence of Cardiac Pacemaker Programming Modes on Exercise Capacity
(Your Name) has sent you a message from In Vivo
(Your Name) thought you would like to see the In Vivo web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
5 + 10 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.
Citation Tools
The Influence of Cardiac Pacemaker Programming Modes on Exercise Capacity
BOGDAN CALOIAN, ADELA VIVIANA SITAR-TAUT, GABRIEL NICOLAE GUSETU, DANA POP, DUMITRU TUDOR ZDRENGHEA
In Vivo Mar 2018, 32 (2) 419-424;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Reprints and Permissions
Share
The Influence of Cardiac Pacemaker Programming Modes on Exercise Capacity
BOGDAN CALOIAN, ADELA VIVIANA SITAR-TAUT, GABRIEL NICOLAE GUSETU, DANA POP, DUMITRU TUDOR ZDRENGHEA
In Vivo Mar 2018, 32 (2) 419-424;
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Materials and Methods
    • Results
    • Discussion
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Sclerotherapy With Polidocanol Is Highly Effective for Treating Oral Cavernous Hemangiomas in Children
  • Survival Predictors in Obstructive Colorectal Cancer: A Combined Clinical, Inflammatory, and Histopathological Approach
  • Ifosfamide, Carboplatin, and Etoposide as Neoadjuvant Chemotherapy in Patients With Neurofibromatosis Type I-related Malignant Peripheral Nerve Sheath Tumors
Show more Clinical Studies

Similar Articles

Keywords

  • Cardiac pacemaker
  • pacemaker programming modes
  • single-chamber pacing
  • dual-chamber pacing
  • rate responsive function
  • exercise capacity
In Vivo

© 2025 In Vivo